OBJECTIVES The purpose of this study was to determine the characteristics of double potentials (DPs) that are helpful in guiding ablation within the cavo-tricuspid isthmus. BACKGROUND Double potentials have been considered a reliable criterion of cavo-tricuspid isthmus block in patients undergoing radiofrequency ablation of typical atrial flutter (AFL). However, the minimal degree of separation of the two components of DPs needed to indicate complete block has not been well defined. METHODS Radiofrequency ablation was performed in 30 patients with isthmus-dependent AFL. Bipolar electrograms were recorded along the ablation line during proximal coronary sinus pacing at sites at which radiofrequency ablation resulted in incomplete or complete isthmus block. RESULTS Double potentials were observed at 42% of recording sites when there was incomplete isthmus block, compared with 100% of recording sites when the block was complete. The mean intervals separating the two components of DPs were 65 +/- 21 ms and 135 +/- 30 ms during incomplete and complete block, respectively (p < 0.001). An interval separating the two components of DPs (DP(1-2) interval) <90 ms was always associated with a local gap, whereas a DP(1-2) interval > or =110 ms was always associated with local block. When the DP(1-2) interval was between 90 and 110 ms, an isoelectric segment within the DP and a negative polarity in the second component of the DP were helpful in indicating local isthmus block. A DP(1-2) interval > or =90 ms with a maximal variation of 15 ms along the entire ablation line was an indicator of complete block in the cavo-tricuspid isthmus. CONCLUSIONS Detailed analysis of DPs is helpful in identifying gaps in the ablation line and in distinguishing complete from incomplete isthmus block in patients undergoing radiofrequency ablation of typical AFL.
منابع مشابه
Catheter ablation of typical atrial flutter: a randomized comparison of 2 methods for determining complete bidirectional isthmus block.
BACKGROUND Complete bidirectional isthmus conduction block (CBIB) was initially assessed by sequential detailed activation mapping at both sides of the ablation line during proximal coronary sinus and anteroinferior right atrium pacing. Mapping only the ablation line ("on-site" atrial potential analysis) was recently reported as a means of CBIB identification. The study was designed to compare ...
متن کاملPartial cavotricuspid isthmus block before ablation in patients with typical atrial flutter.
OBJECTIVES The purpose of this study was to prospectively evaluate preexisting partial isthmus block in the context of an electrophysiologically directed linear ablation strategy for typical atrial flutter (AF). BACKGROUND Double potentials (DPs) separated by an isoelectric interval have been recognized as markers of local block. However, the presence and significance of DPs in the cavotricus...
متن کاملElectrogram polarity and cavotricuspid isthmus block during ablation of typical atrial flutter.
INTRODUCTION The atrial activation sequence around the tricuspid annulus has been used to assess whether complete block has been achieved across the cavotricuspid isthmus during radiofrequency ablation of typical atrial flutter. However, sometimes the atrial activation sequence does not clearly establish the presence or absence of complete block. The purpose of this study was to determine wheth...
متن کاملRandomized comparison of anatomic and electrogram mapping approaches to ablation of typical atrial flutter.
INTRODUCTION The cavotricuspid isthmus can be ablated using an anatomic approach or an electrogram mapping approach in which sites at which there is a gap in the line of block are targeted. The aim of this study was to compare the anatomic and electrogram mapping approaches for creating a line of block in the cavotricuspid isthmus after an initial, unsuccessful anatomically directed ablation li...
متن کاملSuccessful irrigated-tip catheter ablation of atrial flutter resistant to conventional radiofrequency ablation.
BACKGROUND Catheter ablation of typical right atrial flutter is now widely performed. The best end point has been demonstrated to be bidirectional isthmus block. We investigated the use of irrigated-tip catheters in a small subset of patients who failed isthmus ablation with conventional radiofrequency (RF) ablation. METHODS AND RESULTS Of 170 patients referred for ablation of common atrial f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 38 3 شماره
صفحات -
تاریخ انتشار 2001