Influence of hemolysis on the serum lactate dehydrogenase-1/lactate dehydrogenase-2 ratio as determined by an accurate thin-layer agarose electrophoresis procedure.

نویسندگان

  • F Y Leung
  • A R Henderson
چکیده

The accuracy of our lactate dehydrogenase (EC 1.1.1.27) isoenzyme procedure, based on electrophoresis in thin-layer agarose, has previously been assessed (Clin. Chem. 22: 1995, 1976). We now show that the method is similarly accurate and precise for the specific measurements of lactate dehydrogenase isoenzyme-1 and -2. We have also determined the lactate dehydrogenase isoenzyme pattern in peripheral erythrocytes and have found that lactate dehydrogenase-1 is usually the isoenzyme present in greatest concentration. Therefore, hemolysis may increase lactate dehydrogenase-1 in serum, affecting the lactate dehydrogenase isoenzyme ratio used in the diagnosis of myocardial infarction. This conjecture has been confirmed by in vitro experiments, and in a small group of patients with intra-vascular hemolysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Glucose estimated with a Beckman Glucose Analyzer 2 in spots of capillary blood on filter paper.

1. Papadopoulos, N. M., and Hufnagel, C. A., Evaluation of lactate dehydrogenase isoenzyme patterns in serum of patients undergoing cardiac surgery. J. Thorac. Cardiovasc. Surg. 76, 173-177 (1978). 2. McKenzie, D., Clarke, P. I., and Henderson, A. R., How accurate are lactate dehydrogenase isoenzyme estimations by the thin-layer agarose fluorescent technique? Clin. Chem. 22, 1995-1998 (1976). 3...

متن کامل

Glucose Estimated with a Beckman Glucose Analyzer 2 In Spots of Capillary Blood on Filter

1. Papadopoulos, N. M., and Hufnagel, C. A., Evaluation of lactate dehydrogenase isoenzyme patterns in serum of patients undergoing cardiac surgery. J. Thorac. Cardiovasc. Surg. 76, 173-177 (1978). 2. McKenzie, D., Clarke, P. I., and Henderson, A. R., How accurate are lactate dehydrogenase isoenzyme estimations by the thin-layer agarose fluorescent technique? Clin. Chem. 22, 1995-1998 (1976). 3...

متن کامل

Thin-layer agarose electrophoresis of lactate dehydrogenase isoenzymes in serum: a note on the method of reporting and on the lactate dehydrogenase isoenzyme-1/isoenzyme-2 ratio in acute myocardial infarction.

We assessed the clinical efficacy of a thin-layer agarose electrophoresis assay for lactate dehydrogenase isoenzyme estimation in the diagnosis of acute myocardial infarction. From a population of 228 patients admitted to the Coronary Care Unit with suspected acute myocardial infarction, all 101 positive cases (confirmed by clinical presentation and electrocardiographic changes) were correctly ...

متن کامل

Partial characterization, properties, and clinical significance of a lactate dehydrogenase-immunoglobulin A kappa complex in serum.

The existence of a lactate dehydrogenase-immunoglobulin A kappa complex was demonstrated as a marked increase of lactate dehydrogenase activity at the lactate dehydrogenase-3 band in the agar-agarose gel-electrophoresis pattern of sera from seven patients from an unselected group of 21 800 patients. The complex was isolated, in an almost pure form, by gel filtration and affinity chromatography,...

متن کامل

Partial characterization of an abnormal lactate dehydrogenase isoenzyme, LDH-1ex, in serum from a patient with hepatocellular carcinoma.

Serum from a patient with hepatocellular carcinoma contained an abnormal isoenzyme of lactate dehydrogenase (LDH; EC 1.1.1.27), LDH-1ex, that on electrophoresis on 10-g/L agarose gel migrated anodally to the LDH-1 band. This isoenzyme was partly purified by ultrafiltration and preparative electrophoresis. Gel chromatography and sodium dodecyl sulfate/polyacrylamide gel electrophoresis studies o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 27 10  شماره 

صفحات  -

تاریخ انتشار 1981