Increasing the quantitative credibility of open-path Fourier transform infrared (FT-IR) spectroscopic data, with focus on several properties of the background spectrum.

نویسندگان

  • Limin Shao
  • Wanping Wang
  • Peter R Griffiths
  • April B Leytem
چکیده

The choice of the type of background spectrum affects the credibility of open-path Fourier transform infrared spectroscopy (OP/FT-IR) data, and consequently, the quality of data analysis. We systematically investigated several properties of the background spectrum. The results show that a short-path background measured with the lowest amplifier gain could significantly reduce noise in the calculated absorbance spectrum, by at least 30% in our case. We demonstrated that by using a short-path background, data analysis is more resistant to interferences such as wavenumber shift or resolution alteration that occurs as a consequence of aging hardware or misalignment. We discussed a systematic error introduced into quantitative analyses by the short-path background and developed a procedure to correct that error. With this correction approach, a short-path background established five years ago was still found to be valid. By incorporating these findings into the protocol for quantitative analysis, we processed the measurements with two OP/FT-IR instruments set up side by side in the vicinity of a large dairy farm, to monitor NH3, CH4, and N2O. The two sets of calculated concentrations showed high agreement with each other. The findings of our investigations are helpful to atmospheric monitoring practitioners of OP/FT-IR spectroscopy and could also be a reference for future amendments to the protocols outlined in the guidelines of the U.S. Environmental Protection Agency, the American Society for Testing and Materials, and the European Committee for Standardization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

EXCESS THERMODYNAMIC PROPERTIES CALCULATIONS FOR ALCOHOLS IN INERT SOLVENTS BASED ON FOURIER TRANSFORM INFRARED SPECTROSCOPY MEASUREMENTS

Self-association of alcohols; including ethanol, methanol, cyclopentanol and octanol in separate mixtures with inert solvents have been studied using FT-IR spectroscopy. Except for the band at 3640 cm–1 in the IR spectrum of the alcohols which is due to the monomer species, the presence of other bands in the region of stretching vibrational frequencies of OH (3100-3700 cm–1) are attributed to t...

متن کامل

Advances in data processing for open-path Fourier transform infrared spectrometry of greenhouse gases.

The automated quantification of three greenhouse gases, ammonia, methane, and nitrous oxide, in the vicinity of a large dairy farm by open-path Fourier transform infrared (OP/FT-IR) spectrometry at intervals of 5 min is demonstrated. Spectral pretreatment, including the automated detection and correction of the effect of interrupting the infrared beam, is by a moving object, and the automated c...

متن کامل

What Is an Ft-ir and an Ft-ir Spectrometer?

An FT-IR Spectrometer is an instrument which acquires broadband NIR to FIR spectra. Unlike a dispersive instrument, i.e. grating monochromator or spectrograph, an FT-IR Spectrometer collects all wavelengths simultaneously. This feature, called the Multiplex or Felgett Advantage, is discussed in detail on page 3. FT-IR Spectrometers are often simply called FT-IRs. But for the purists, an FT-IR (...

متن کامل

Recovery of absorption spectra from Fourier transform infrared (FT-IR) microspectroscopic measurements of intact spheres.

An infrared spectrum recorded from a microscopic sample depends on spectral properties of the constituent material as well as on morphology. Many samples or domains within heterogeneous materials can be idealized as spheres, in which both scattering and absorption from the three-dimensional shape affect the recorded spectrum. Spectra recorded from such objects may be altered to such an extent t...

متن کامل

Obtaining qualitative information on trace species in continuous open-path fourier transform spectroscopic measurements using target factor analysis and related techniques.

We report the application of target factor analysis (TFA) to the identification of trace analytes in open-path Fourier transform infrared (OP/FT-IR) spectra. Results showed that for components such as methane and ammonia, for which the path-integrated concentration was greater than approximately 100 ppm.m, TFA yielded results that closely match corresponding reference spectra. Furthermore, it w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied spectroscopy

دوره 67 3  شماره 

صفحات  -

تاریخ انتشار 2013