fMRI analysis with the general linear model: removal of latency-induced amplitude bias by incorporation of hemodynamic derivative terms.
نویسندگان
چکیده
Functional magnetic resonance imaging (fMRI) data are often analyzed using the general linear model employing a hypothesized neural model convolved with a hemodynamic response function. Mismatches between this hemodynamic model and the data can be induced by spatially varying delays or slice-timing differences. It is common practice to desensitize the analysis to such delays by incorporation of the hemodynamic model plus its temporal derivative. The rationale often used is that additional variance will be captured and regressed out from the data. Though this is true, it ignores the potential for amplitude bias induced by small model mismatches due to, for example, variable hemodynamic delays and is not helpful for "random effects" analyses which typically do not account for the first level variance at all. Amplitude bias is due to the use of only the nonderivative portion of the model in the final test for significant amplitudes. We propose instead testing an amplitude value that is a function of both the nonderivative and the derivative terms of the model. Using simulations, we show that the proposed amplitude test does not suffer from delay-induced bias and that a model incorporating temporal derivatives is a more natural test for amplitude differences. The proposed test is applied in a random-effects analysis of 100 subjects. It reveals increased amplitudes in areas consistent with the task, with the largest increases in regions with greater hemodynamic delays.
منابع مشابه
Detecting fMRI activation allowing for unknown latency of the hemodynamic response.
Several authors have suggested allowing for unknown latency of the hemodynamic response by incorporation of hemodynamic derivative terms into the linear model for the statistical analysis of fMRI data. In this paper, we show how to use random field theory to provide a P value for local maxima of two test statistics that have been recently proposed for detecting activation based on this analysis.
متن کاملModeling the hemodynamic response function in fMRI: Efficiency, bias and mis-modeling
Most brain research to date have focused on studying the amplitude of evoked fMRI responses, though there has recently been an increased interest in measuring onset, peak latency and duration of the responses as well. A number of modeling procedures provide measures of the latency and duration of fMRI responses. In this work we compare several techniques that vary in their assumptions, model co...
متن کاملPros and Cons of Using the Informed Basis Set to Account for Hemodynamic Response Variability with Developmental Data
Conventional analysis of functional magnetic resonance imaging (fMRI) data using the general linear model (GLM) employs a neural model convolved with a canonical hemodynamic response function (HRF) peaking 5 s after stimulation. Incorporation of a further basis function, namely the canonical HRF temporal derivative, accounts for delays in the hemodynamic response to neural activity. A populatio...
متن کاملLocally Estimated Hemodynamic Response Function and Activation Detection Sensitivity in Heroin-Cue Reactivity Study
Introduction: A fixed hemodynamic response function (HRF) is commonly used for functional magnetic resonance imaging (fMRI) analysis. However, HRF may vary from region to region and subject to subject. We investigated the effect of locally estimated HRF (in functionally homogenous parcels) on activation detection sensitivity in a heroin cue reactivity study. Methods: We proposed...
متن کاملA weighted least-squares algorithm for estimation and visualization of relative latencies in event-related functional MRI.
The properties of the hemodynamic latencies in functional maps have been relatively unexplored. Accurate methods of estimating hemodynamic latencies are needed to take advantage of this feature of fMRI. A fully automated, weighted least-squares (WLS) method for estimating temporal latencies is reported. Using a weighted linear model, the optimal latency and amplitude of the fMRI response can be...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- NeuroImage
دوره 22 1 شماره
صفحات -
تاریخ انتشار 2004