Scaling in readout direction: a vibration-induced distortion of diffusion-weighted images and its retrospective correction by affine registration
نویسندگان
چکیده
Introduction: Diffusion tensor imaging (DTI) offers the possibility of estimating quantities that are related to the brain’s white matter (WM) microstructure, e.g. the fractional anisotropy (FA) [1].These quantities are frequently used for group comparisons (e.g. [2]). For DTI, at least seven images must be acquired [3]: one image with no diffusion sensitization (b0 image), and six diffusion-weighted (DW) images with diffusion sensitization in noncollinear directions. The large diffusion gradients lobes cause different kinds of MR artifacts like eddy current (EC) and vibration effects [4,5,6]. While EC effects could significantly be reduced by using a twice-refocused spin echo (TRSE) sequence for DTI acquisition [7], the vibration effects become more evident when the TRSE sequence is used [5]. Parts of the EC distortions can also be corrected retrospectively by registering the DW images on the nondiffusion-weighted image [4,8,9]. However, up to now no vibration-induced geometrical distortion of the DW images has been identified that could be retrospectively corrected. This study is a continuation of previous investigation of EC-induced whole-brain distortions, where the focus is now on vibration-induced distortions. Objectives: (i) To show that the linear vibration-induced motion effects can lead to a whole-brain scaling of the DW images. (ii) To show that the x scaling that is determined by retrospective correction of MR artifacts is not related to EC effects and that it can be used to correct and assess vibration effects. Methods: Two groups of, respectively 13 and 14 healthy right-handed subjects participated in this study. DTI data were acquired at 3T. The first group (DTI1) was investigated on a Gyronscan Intera (Philips, Best, The Netherlands) with a birdcage head coil and a pulsed gradient spin echo (PGSE) sequence (20 DW and 3 b0 images, NEX=2, matrix 128, 36 slices, thickness 3.6mm). The second group (DTI2) was investigated on a MAGNETOM TIM Trio (Siemens, Erlangen, Germany) with an 8-channel array and a TRSE sequence (60 DW and 7 b0 images, matrix 128, 72 slices, thickness 1.8mm). In analysis (i) we modeled the point-spread function (PSF) that is subject to a linear vibrationinduced in-plane motion. We calculate the effective voxel size by the FWHM of the central lobe of the PSF [10]. In analysis (ii) we investigate the contribution of the x scaling and whole-brain EC parameters to the improvement of the tensor estimation, if two DTI data sets (DTI1 and DTI2) that differ in the EC and vibration effects are investigated. For this purpose, we used the relative error: 12 12 11 σ σ − σ = ε ∂ ) ) ( ( ) ( pi pi , where σ12 is the tensor error [8] calculated after correcting the MR artifacts by a 12-parameter-affine registration, and σ11(pi) is the tensor error after correcting the MR artifacts by a 11parameter registration that is derived from the 12-parameter registration by fixing the parameter pi (see Fig. 2). Results and Discussion: (i) Linear motion in x-direction leads to broadening of the effective voxel size that is symmetric in x and y; whereas the linear motion in y-direction solely leads to broadening of the effective voxel size in y direction (Fig. 1). (ii) Taking the EC parameter into account leads to an improvement of the tensor error that is greater for the DTI1 data set relative to the DTI2 data set (Fig. 2). These results are in accordance with previous observations that the EC effects are smaller in the DTI data acquired by TRSE (DTI2) relative to PGSE (DTI1) [7]. Furthermore, we showed that taking the vibration parameter p7 into account leads to an improvement of the relative error that is greater for the data set DTI2 relative to DTI1. Again, these results are in accordance with previous observation showing that vibration effects are greater for DTI data acquired by TRSE relative to PGSE [5]. The scaling parameters sx were between 0.995 and 0.997; this results in a linear shifting parameter between 0.2 and 0.7 mm (Fig. 3). This range agrees with experimentally determined shifting parameters [5]. Conclusion: We showed that the vibration-induced motion leads to an affine scaling effect in x and y-direction. While the scaling in y-direction is also subject to EC-induced distortions and thus cannot be correlated to vibration effects, the x-scaling seems to correct solely vibration-induced scaling effects. Thus, it might be a value that can be used for comparing vibration effects in different DTI data sets. References: [1] Pierpaoli et al., MRM 36, 893 (‘96), [2] Deppe et al., Neurology 71, 1981 (‘09), [3] Basser et al., JMR B 103, 247 (‘94), [4] Haselgrove et al., MRM 36, 960 (‘96), [5] Hiltunen et al., NI 32, 93 (‘06), [6] Gallichan et al., HBM, in press, [7] Reese et al., MRM 49, 177 (‘03), [8] Andersson and Skare, NI 17, 177 (‘02), [9] Mohammadi ISMRM 17, 1405 (‘09), [10] Liang and Lauterbur, IEEE Press, Inc. NY (‘00). Fig. 1-3: (1) Absolute value of the 2-dim. PSF for different shifting parameters in x direction ΔLx and y direction ΔLy (PSF parameters: N=100; gridding: 0.05;Δk=1/128). (2) Relative error of the whole-brain EC parameters (y-translation: p2, y-scaling: p8, in-plane shearing: p10, and through-plane shearing: p11) and of the vibration-induced x-scaling (p7) for DTI1 (a) and DTI2 (b). (3) Modeled scaling parameter for two limiting cases: (a) for ΔLx=0 as a function of ΔLy (green); (b) for ΔLy=0 as a function of ΔLx (red).
منابع مشابه
An Algorithm for Moment-Based Global Registration of Echo Planar Diffusion-Weighted Images
G. Kindlmann1, A. L. Alexander2,3, M. Lazar2,3, J. Lee2, T. Tasdizen1, R. Whitaker1 Computer Science, University of Utah, Salt Lake City, UT, United States, Medical Physics, University of Wisconsin, Madison, WI, United States, W.M. Keck Lab, University of Wisconsin, Madison, WI, United States Introduction In a diffusion-weighted imaging experiment, the strong diffusion-sensitizing gradients can...
متن کاملQuantitative Simulation of Affine Registration for Correction of Eddy Current Distortions in Diffusion-Weighted Images
R. G. Nunes, I. Drobnjak, S. Clare, P. Jezzard, M. Jenkinson Centre for Functional MRI of the Brain, University of Oxford, Oxford, United Kingdom Introduction: Diffusion-weighted (DW) imaging has shown great potential for mapping white matter tracts in the brain [1]. In order to be able to infer on fibre structure, DW images need to be collected under a set of different diffusion gradient direc...
متن کاملFieldmap-Free Retrospective Registration and Distortion Correction for EPI-based Diffusion-Weighted Imaging
Introduction Acquisition of a set Diffusion Weighted Images (DWIs) allows Diffusion Tensors and Tensor-derived quantities such as Fractional Anisotropy (FA) and Trace (TR) to be computed and used to infer the underlying white matter structure in the brain. DWIs are usually acquired with an echo-planar imaging (EPI) pulse sequence that produces images degraded by B0 field inhomogeneity, eddy cur...
متن کاملCorrecting eddy current and motion effects by affine whole-brain registrations: evaluation of three-dimensional distortions and comparison with slicewise correction.
Eddy-current (EC) and motion effects in diffusion-tensor imaging (DTI) bias the estimation of quantitative diffusion indices, such as the fractional anisotropy. Both effects can be retrospectively corrected by registering the strongly distorted diffusion-weighted images to less-distorted T2-weighted images acquired without diffusion weighting. Two different affine spatial transformations are us...
متن کاملComprehensive approach for correction of motion and distortion in diffusion-weighted MRI.
Patient motion and image distortion induced by eddy currents cause artifacts in maps of diffusion parameters computed from diffusion-weighted (DW) images. A novel and comprehensive approach to correct for spatial misalignment of DW imaging (DWI) volumes acquired with different strengths and orientations of the diffusion sensitizing gradients is presented. This approach uses a mutual information...
متن کامل