Bnl-65970 Informal Report Detection of Interstate Liquids Pipeline Leaks: Feasibility Evaluation

نویسندگان

  • R. N. DIETZ
  • G. I. SENUM
  • Russell N. Dietz
  • Gunnar I. Senum
چکیده

The approximately 200,000-mile fuel pipeline system in the U.S. operates at flow rates up to 2.5 x 10 gallons per hour (GPH). Most commercial technologies only provide on-line leak detection at about 0.3% of flow rate, i.e., about 7,500 GPH or larger. Detection of leaks at about 1 GPH or so is desirable both from a regulatory and leak-prevention standpoint. Brookhaven’s commercially-accepted perfluorocarbon tracer (PFT) technology for underground leak detection of utility industry dielectric fluids at leak rates less than 0.1 GPH, with new enhancements, will be able to cost-effectively detect fuel pipeline system leaks to about 1 GPH—3 orders-of-magnitude better than any on-line system. The magnitude of detected leaks would be calculable as well. Proposed mobile surveys (such as those used periodically in the gas pipeline industry) at about 110 to 120 miles per day would allow such small leaks to be detected at 10-ppb tagging levels (less than $1,500 of PFT for a 48-hour tag at the maximum transport rate) under worst-case meteorological dispersion conditions. Smaller leaks could be detected by proportionately larger tagging concentrations. Leaks would be pinpointed by subsequent conventional barholing and vapor analyses. There are no health nor safety issues associated with the use of the proposed technological approach nor any consequential environmental impacts associated with the proposed magnitudes of PFT tagging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

INVERSE FREQUENCY RESPONSE ANALYSIS FOR PIPELINES LEAK DETECTION USING THE PARTICLE SWARM OPTIMIZATION

Inverse Transient Analysis (ITA) is a powerful approach for leak detection of pipelines. When the pipe transient flow is analyzed in frequency domain the ITA is called Inverse Frequency Response Analysis (IFRA). To implement an IFRA for leak detection, a transient state is initiated in the pipe by fast closure of the downstream end valve. Then, the pressure time history at the valve location is...

متن کامل

Natural Gas Compressor Stations on the Interstate Pipeline Network: Developments Since 1996

This special report looks at the use of natural gas pipeline compressor stations on the interstate natural gas pipeline network that serves the lower 48 States. It examines the compression facilities added over the past 10 years and how the expansions have supported pipeline capacity growth intended to meet the increasing demand for natural gas. Questions or comments on the contents of this art...

متن کامل

State-of-the-Art in Leak Detection and Localisation

Many fluids transported by pipelines are hazardous. It is therefore often necessary to install leak detection (and localization) systems (LDS), especially due to legal regulations like • the “Code for Federal Regulations (CFR) Title 49 Part 195” [1], API 1130 2 Ed. [2], both for the USA, or • the “Technische Regeln für Fernleitungen” (TRFL) (Technical Rules for Pipelines) in Germany [5]. This p...

متن کامل

Analysis of Failure Caused by In-service Welding in anX52 Gas Pipeline

In the research presented in this paper, a failure analysis were carried out to identify causes of an incident, which had taken place after an operation to repair a leak in an interstate natural gas pipeline. In this operation, a partial encirclement reinforcement (patch) was welded to the carrier pipe according to an available hot taping procedure, while gas was flowing in the pipeline. The fa...

متن کامل

A Hardware for Processing Magnetic Pressure Sensor Signals from Leak Detection in Waterworks

Leaks in pipelines and waterworks are detected using different methods and among them spectral analysis is one of the most interesting ones. Sources of signals to be processed are different, for example: reflected signals from ground penetrating radar and acoustic sources, signals from dedicated sensors mounted on pipelines, etc... In the latter case, magnetic pressure sensors located on the pi...