Stent conformity in curved vascular models with simulated aneurysm necks using flat-panel CT: an in vitro study.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Radiographic visibility of self-expandable intracranial stents is insufficient for assessment of conformability and deployment characteristics. The purpose of this study was to evaluate stent mechanics in a curved vessel model by using Flat-Panel CT (FPCT). MATERIALS AND METHODS The following stents were used: Neuroform 2, Neuroform Treo, Enterprise, and LEO. All stents were bent in the same polytetrafluoroethylene tubes with various angles ranging from 150 degrees to 30 degrees . To visualize potential prolapse of the stent struts, 4-, 5-, and 8-mm openings were created. FPCTs were obtained using a C-arm with flat detector. RESULTS FPCT scans provided excellent visualization of deployment characteristics and stent mechanics and was superior to digital subtraction angiography (DSA) and digital radiography (DR). The Neuroform2/Treo showed, with increasing angle and diameter of the opening, a continuous increase in cell size. These stents also showed an outward prolapse at the convexity and an inwards prolapse of struts at the concavity of the curvature. The Enterprise showed an increasing trend to flatten and to kink with curvatures that are more acute. The LEO showed fewer trends to kink but an inward crimping of its ends with more acute angles. CONCLUSIONS Deployment characteristics and conformability to a curved vessel model vary considerably, depending on the angle and the stent design. Adverse mechanics such as increased cell opening, strut prolapse, flattening, and kinking occur during stent placement in a curved vessel model, and may gain clinical importance. FPCT is superior to DSA and DR in visualizing small metallic stents and enables accurate detection of adverse stent mechanics.
منابع مشابه
Assessment of abdominal aortic aneurysms using a cone-beam CT system: an experimental phantom study and an initial clinical evaluation before and after stent-graft treatment in patients with an abdominal aortic aneurysm.
The aim of this study is to conduct a quantitative analysis of cone-beam CT (CBCT) images using a phantom, and then to evaluate the clinical usefulness of CBCT in the assessment of abdominal aortic aneurysms (AAA) before and after stent-grafting, both qualitatively as well as quantitatively. The phantom used in this study was a rectangular plate made of an acrylic resin, which contained eight t...
متن کاملDelivery technique plays an important role in determining vessel wall apposition of the Enterprise self-expanding intracranial stent
BACKGROUND The Enterprise (EN) vascular reconstruction device is a self-expanding nitinol stent used as adjunctive support in wide-necked aneurysm coiling. We sought to evaluate the effect of deployment technique on how well the EN stent conforms to the vessel wall around a curve. METHODS A flow model consisting of a 3.5 mm diameter silicone tube forming a 7 mm radius curve was visualized usi...
متن کاملEndovascular Treatment of Isolated Common Iliac Artery Aneurysms With Short Necks Using Bifurcated Stent-Grafts
Elective surgical repair has traditionally been considered to be the treatment of choice for the exclusion of isolated iliac artery aneurysms (IAAs). Recently, endovascular repair has evolved as an alternative to surgical repair, especially in patients at high surgical risk. However, in the absence of sufficient proximal necks, iliac artery aneurysms are not suitable for direct deployment of a ...
متن کاملSaccular aneurysms on straight and curved vessels are subject to different hemodynamics: implications of intravascular stenting.
Our aim was to examine hemodynamic implications of intravascular stenting in the canine venous pouch (sidewall or straight-vessel) and rabbit elastase (curved-vessel) aneurysm models. Flow dynamics in stented (Wallstent) and nonstented versions were studied by using computational fluid dynamics simulations and in vitro flow visualization, with a focus on stent placement effects on aneurysmal fl...
متن کاملThe Prevalence and Properties of Intracranial Vascular Abnormalities in CT Angiography of Patients with Non-traumatic Intracranial Hemorrhage
Introduction:Intracranial hemorrhage (ICH) is divided into two traumatic and non-traumatic categories. The present study sought to investigate the anatomical properties of non-traumatic intracranial hemorrhage in Kerman, Iran. Method:A total of 305 non-traumatic ICH cases were chosen in Shafa medical center. Data from patients’ files and CT scan images, including demographic factors and type o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 28 5 شماره
صفحات -
تاریخ انتشار 2007