Adaptive optics visual simulator.
نویسندگان
چکیده
PURPOSE To develop a prototype instrument that uses adaptive optics to introduce virtually any desired aberration profile in a subject's eye. At the same time, the instrument could be used to evaluate the subject's spatial vision for each controlled aberration profile. This "aberration testing station" or "visual simulator" allows us to study the relationship between specific aberrations and visual quality. METHODS The apparatus uses infrared light to measure the wavefront aberration of the system plus the eye with a Hartmann-Shack wavefront sensor. Defocus is added (or removed) with a computer-controlled, motorized optometer, while higher order aberrations are introduced by a 37-channel membrane deformable mirror. A parallel viewing channel is used for visual testing with the instrument. Visual acuity, contrast sensitivity, and other visual tests are performed under normal viewing for each desired aberration profile. RESULTS The range of defocus that can be added is nearly unlimited, while the maximum amount of other aberration modes is restricted to approximately 0.5 microm, depending on mode. Pure modes or any selected combination of modes can be produced with high repeatability and precision (usually better than 0.05 microm), and the system works for pupil diameters up to 6 mm (with a natural pupil). CONCLUSIONS The adaptive optics visual simulator is a powerful, non-invasive tool to evaluate how aberrations affect vision. In addition, it can be used for the interactive design and testing of new ophthalmic devices, and for the simulation of visual outcomes in customized refractive surgery.
منابع مشابه
Liquid crystal Adaptive Optics Visual Simulator: Application to testing and design of ophthalmic optical elements.
The concept of Adaptive Optics Visual Simulation applies to the use of an Adaptive Optics system to manipulate ocular aberrations in order to perform visual testing through a modified optics. It can be of interest both to study the visual system and to design new ophthalmic optical elements. In this work, we describe an apparatus based on a liquid crystal programmable phase modulator and explor...
متن کاملUse of adaptive optics to determine the optimal ocular spherical aberration.
PURPOSE To explore the impact of spherical aberration (SA) on contrast sensitivity using an adaptive optics vision simulator to determine the optimal amount of SA to include in customized corrections of wavefront aberrations. SETTING Laboratorio de Optica, Universidad de Murcia, Murcia, Spain, and AMO Groningen BV, Groningen, The Netherlands. METHODS An adaptive optics vision simulator cons...
متن کاملAdaptive optics simulation of intraocular lenses with modified spherical aberration.
PURPOSE Adaptive optics systems can be used to investigate the potential visual benefit associated with correcting ocular wave-front aberration. In this study, adaptive optics techniques were used to evaluate the potential advantages and disadvantages associated with intraocular lenses (IOLs) with modified spherical aberration profiles. METHODS An adaptive optics vision simulator was construc...
متن کاملDynamic wave-front distortion compensation with a 134-control-channel submillisecond adaptive system.
A 134-control-channel adaptive-optics system consisting of a microelectromechanical mirror array (mu -mirror), a wave-front tilt-control mirror, and a very large scale integration controller utilizing a stochastic gradient-descent optimization of a performance metric is presented. A maximum adaptation rate of ~11, 000 iterations/s was achieved. The system was used to demonstrate real-time compe...
متن کاملBinocular visual performance with aberration correction as a function of light level.
The extent to which monocular visual performance of subjects with normal amounts of ocular aberrations can be improved with adaptive optics (AO) depends on both the pupil diameter and the luminance for visual testing. Here, the benefit of correction of higher order aberrations for binocular visual performance was assessed over a range of luminances for natural light-adapted pupil sizes with a b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of refractive surgery
دوره 18 5 شماره
صفحات -
تاریخ انتشار 2002