Improved precision in SASHA T1 mapping with a variable flip angle readout

نویسندگان

  • Kelvin Chow
  • Bruce S Spottiswoode
  • Joseph J Pagano
  • Richard B Thompson
چکیده

Background The SAturation-recovery single-SHot Acquisition (SASHA) T1 mapping sequence has excellent accuracy independent of T1, T2, heart rate, and flip angle [1], which are known dependencies of the more commonly used MOdified Look-Locker Inversion-recovery (MOLLI) sequence. However, SASHA has a greater T1 variability (poorer precision) compared to MOLLI. A two-parameter fit, with assumed ideal saturation, has been shown to improve precision compared to the standard three-parameter fit used for SASHA, but at the expense of introducing systematic errors [2]. We propose that a variable flip angle (VFA) readout will reduce these systematic errors and thereby allow the improved precision of a two-parameter fit while maintaining the accuracy of the three-parameter fit.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Variability of T1 in purpose recruited normal volunteers and patients as a function of shim (B0), flip angle (B1) and myocardial sector at 3T

Methods 36 subjects (including 20 normal volunteers) were scanned using an investigational prototype sequence on a 3T scanner (MAGNETOM Skyra, Siemens AG, Germany). T1 was measured using three Methods MOLLI with a flip angle of 20 ̊, MOLLI with flip angle 35 ̊, and 2-parameter SASHA with a variable flip angle (VFA) readout. B0 and B1 field maps were generated. Sector level, intra-subject, between...

متن کامل

Robust free-breathing SASHA T1 mapping with high-contrast image registration

BACKGROUND Many widely used myocardial T1 mapping sequences use breath-hold acquisitions that limit the precision of calculated T1 maps. The SAturation-recovery single-SHot Acquisition (SASHA) sequence has high accuracy with robustness against systematic confounders, but has poorer precision compared to the commonly used MOdified Look-Locker Inversion recovery (MOLLI) sequence. We propose a nov...

متن کامل

Selection of magnetization catalyzation and readout methods for modified Look-Locker inversion recovery: a T1 mapping primer.

BACKGROUND The purpose of this work was to evaluate different magnetization preparation and readout sequences for modified Look-Locker inversion recovery (MOLLI) toward improved T1 mapping in the heart. Elements investigated include: catalyzation sequences to prepare the magnetization before readout, alternate k-space trajectories, a spoiled gradient recalled echo readout, and a 5b(3b)3b MOLLI ...

متن کامل

Wide-Range T1 Mapping Using Two Variable Flip Angle Acquisitions

Introduction: Volumetric T1 mapping using two variable flip angle (VFA) acquisitions has become a popular clinical tool for T1 estimation due to short scan times and ease of implementation. The conventional approach to flip angle selection has been based on maximization of the signaldynamic range (S-DR) product for a single T1 value of interest (typically ≤ 1000 ms), with estimation accuracy an...

متن کامل

Flip angle-optimized fast dynamic T1 mapping with a 3D gradient echo sequence.

PURPOSE To analyze the flip angle dependence and to optimize the statistical precision of a fast three-dimensional (3D) T1 mapping technique based on the variable flip angle (VFA) method. The proposed single flip angle (1FA) approach acquires only a single 3D spoiled gradient echo data set for each time point of the dynamical series in combination with a longer baseline measurement. THEORY AN...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2014