SPAD array chips with full frame readout for crystal characterization
نویسندگان
چکیده
Heidelberg University, Germany We present single photon sensitive 2D camera chips containing 88x88 avalanche photo diodes which can be read out in full frame mode with up to 400.000 frames per second. The sensors have an imaging area of ~5mm x 5mm covered by square pixels of ~56μm × 56μm with a ~55% fill factor in the latest chip generation. The chips contain a self triggering logic with selectable (column) multiplicities of up to >=4 hits within an adjustable coincidence time window. The photon accumulation time window is programmable as well. First prototypes have demonstrated low dark count rates of <50kHz/mm2 (SPAD area) at 10 degree C for 10% masked pixels. One chip version contains an automated readout of the photon cluster position. The readout of the detailed photon distribution for single events allows the characterization of light sharing, optical crosstalk etc., in crystals or crystal arrays as they are used in PET instrumentation. This knowledge could lead to improvements in spatial or temporal resolution.
منابع مشابه
A Full Parallel Event Driven Readout Technique for Area Array SPAD FLIM Image Sensors
This paper presents a full parallel event driven readout method which is implemented in an area array single-photon avalanche diode (SPAD) image sensor for high-speed fluorescence lifetime imaging microscopy (FLIM). The sensor only records and reads out effective time and position information by adopting full parallel event driven readout method, aiming at reducing the amount of data. The image...
متن کاملSmart-aggregation imaging for single molecule localisation with SPAD cameras
Single molecule localisation microscopy (SMLM) has become an essential part of the super-resolution toolbox for probing cellular structure and function. The rapid evolution of these techniques has outstripped detector development and faster, more sensitive cameras are required to further improve localisation certainty. Single-photon avalanche photodiode (SPAD) array cameras offer single-photon ...
متن کاملMAXIPIX, a fast readout photon-counting X-ray area detector for synchrotron applications
A 2D photon-counting X-ray detector system with 1.4 kHz frame rate and 55 μm spatial resolution has been developed and commissionned on ESRF beamlines. The system called MAXIPIX (Multichip Area X-ray detector based on a photon-counting PIXel array) consists of a detector module implementing up to five MEDIPIX-2 or TIMEPIX photon-counting readout chips, a custom readout interface board and a Lin...
متن کاملPILATUS 2M A Detector for Small Angle X-ray Scattering
For the (coherent) small-angle X-ray scattering (SAXS) beamline X12SA of the Swiss Light Source at the Paul Scherrer Institut, a novel X-ray detector is built, the PILATUS 2M. Contributions in module fabrication, detector assembly, characterization and calibration are covered within the framework of this thesis. Furthermore, data analysis of a particular SAXS experiment demonstrating the perfor...
متن کاملHigh-Speed Imaging at High X-ray Energy: CdTe Sensors Coupled to Charge-Integrating Pixel Array Detectors
Pixel Array Detectors (PADs) consist of an x-ray sensor layer bonded pixel-by-pixel to an underlying readout chip. This approach allows both the sensor and the custom pixel electronics to be tailored independently to best match the x-ray imaging requirements. Here we describe the hybridization of CdTe sensors to two different charge-integrating readout chips, the Keck PAD and the Mixed-Mode PAD...