Multicenter Study Validating Accuracy of a Continuous Respiratory Rate Measurement Derived From Pulse Oximetry: A Comparison With Capnography
نویسندگان
چکیده
BACKGROUND Intermittent measurement of respiratory rate via observation is routine in many patient care settings. This approach has several inherent limitations that diminish the clinical utility of these measurements because it is intermittent, susceptible to human error, and requires clinical resources. As an alternative, a software application that derives continuous respiratory rate measurement from a standard pulse oximeter has been developed. We sought to determine the performance characteristics of this new technology by comparison with clinician-reviewed capnography waveforms in both healthy subjects and hospitalized patients in a low-acuity care setting. METHODS Two independent observational studies were conducted to validate the performance of the Medtronic Nellcor Respiration Rate Software application. One study enrolled 26 healthy volunteer subjects in a clinical laboratory, and a second multicenter study enrolled 53 hospitalized patients. During a 30-minute study period taking place while participants were breathing spontaneously, pulse oximeter and nasal/oral capnography waveforms were collected. Pulse oximeter waveforms were processed to determine respiratory rate via the Medtronic Nellcor Respiration Rate Software. Capnography waveforms reviewed by a clinician were used to determine the reference respiratory rate. RESULTS A total of 23,243 paired observations between the pulse oximeter-derived respiratory rate and the capnography reference method were collected and examined. The mean reference-based respiratory rate was 15.3 ± 4.3 breaths per minute with a range of 4 to 34 breaths per minute. The Pearson correlation coefficient between the Medtronic Nellcor Respiration Rate Software values and the capnography reference respiratory rate is reported as a linear correlation, R, as 0.92 ± 0.02 (P < .001), whereas Lin's concordance correlation coefficient indicates an overall agreement of 0.85 ± 0.04 (95% confidence interval [CI] +0.76; +0.93) (healthy volunteers: 0.94 ± 0.02 [95% CI +0.91; +0.97]; hospitalized patients: 0.80 ± 0.06 [95% CI +0.68; +0.92]). The mean bias of the Medtronic Nellcor Respiration Rate Software was 0.18 breaths per minute with a precision (SD) of 1.65 breaths per minute (healthy volunteers: 0.37 ± 0.78 [95% limits of agreement: -1.16; +1.90] breaths per minute; hospitalized patients: 0.07 ± 1.99 [95% limits of agreement: -3.84; +3.97] breaths per minute). The root mean square deviation was 1.35 breaths per minute (healthy volunteers: 0.81; hospitalized patients: 1.60). CONCLUSIONS These data demonstrate the performance of the Medtronic Nellcor Respiration Rate Software in healthy subjects and patients hospitalized in a low-acuity care setting when compared with clinician-reviewed capnography. The observed performance of this technology suggests that it may be a useful adjunct to continuous pulse oximetry monitoring by providing continuous respiratory rate measurements. The potential patient safety benefit of using combined continuous pulse oximetry and respiratory rate monitoring warrants assessment.
منابع مشابه
Capnography is superior to pulse oximetry for the detection of respiratory depression during colonoscopy.
BACKGROUND Pulse oximetry is a widely accepted procedure for ventilatory monitoring during gastrointestinal endoscopy, but this method provides an indirect measurement of the respiratory function. In addition, detection of abnormal ventilatory activity can be delayed, especially if supplemental oxygen is provided. Capnography offers continuous real-time measurement of expiratory carbon dioxide....
متن کاملRespiratory therapies in the critical care setting. Should every mechanically ventilated patient be monitored with capnography from intubation to extubation?
One of the most important aspects of caring for a critically ill patient is monitoring. Few would disagree that the most essential aspect of monitoring is frequent physical assessments. Complementing the physical examination is continuous monitoring of heart rate, respiratory rate, and blood oxygen saturation measured via pulse-oximetry, which have become the standard of care in intensive care ...
متن کاملA Brief Review of Non-invasive Monitoring of Respiratory Condition for Extubated Patients with or at Risk for Obstructive Sleep Apnea after Surgery
Obstructive sleep apnea (OSA) is one of the important risk factors contributing to postoperative airway complications. OSA alters the respiratory physiology and increases the sensitivity of muscle tone of the upper airway after surgery to residual anesthetic medication. In addition, the prevalence of OSA was reported to be much higher among surgical patients than the general population. Therefo...
متن کاملCapnography compared to pulse oximetry for early detection of respiratory compromise in non-intubated patients undergoing gastrointestinal endoscopy procedures: a systematic review protocol.
REVIEW QUESTION/OBJECTIVE Does the use of capnography versus pulse oximetry increase the early detection of respiratory compromise and improve safety in non-intubated patients undergoing moderate sedation for gastrointestinal endoscopy procedures?Respiratory compromise will be detected by alveolar hypoventilation/hyperventilation (EtCO2 < 35 mmHg/EtCO2 > 50 mmHg), arterial oxygen desaturation (...
متن کاملCapnography monitoring enhances safety of postoperative patient-controlled analgesia.
BACKGROUND Patient-controlled analgesia is associated with potentially fatal opioid-related respiratory depression. Opioids are a well-recognized cause of respiratory depression. However, in the postoperative patient, unrecognized pulmonary disease may lead to retention of carbon dioxide, which is further antagonized by opioids and may lead to life-threatening respiratory depression. Therefore,...