Effect of microphone location in ITE versus BTE hearing aids.

نویسندگان

  • E L Gartrell
  • G T Church
چکیده

Sound pressure measurements were made at the hearing aid microphones of 20 subjects with their in-the-ear (ITE) hearing aids and a behind-the-ear (BTE) hearing aid to determine the influence of microphone location on hearing aid input. A probe tube microphone was used to measure the difference in dB SPL between the ITE and BTE microphone locations. ITE microphone location resulted in a maximum high frequency advantage of 9.2 dB in the 2500 to 5000 Hz range. However, the frequency location of this maximal advantage varied a great deal between individuals, precluding the use of a standard ITE microphone correction factor for 2cc coupler to functional gain conversions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Speech recognition with in-the-ear and behind-the-ear dual-microphone hearing instruments.

The primary purpose of this study was to compare the overall listening benefit in diffuse noise provided by dual-microphone technology in an in-the-ear (ITE) hearing instrument to that provided by dual-microphone technology in a behind-the-ear (BTE) hearing instrument. Further, the study was designed to determine whether the use of the dual-microphone + the manufacturer's party response algorit...

متن کامل

The Effect of Microphone Placement on Interaural Level Differences and Sound Localization Across the Horizontal Plane in Bilateral Cochlear Implant Users.

OBJECTIVE This study examined the effect of microphone placement on the interaural level differences (ILDs) available to bilateral cochlear implant (BiCI) users, and the subsequent effects on horizontal-plane sound localization. DESIGN Virtual acoustic stimuli for sound localization testing were created individually for eight BiCI users by making acoustic transfer function measurements for mi...

متن کامل

Probe-microphone measurements with body-worn instruments: loudspeaker and reference microphone effects.

Probe-microphone measurements are typically made with behind-the-ear (BTE) and in-the-ear (ITE) hearing aids with the loudspeaker located at 0-degrees or 45-degrees azimuth at head level and the reference microphone positioned on the head near the hearing aid microphone. With body-worn instruments, these conditions may not accurately reflect in situ hearing aid performance. This study compared ...

متن کامل

Moisture Study on Nano-Coated Hearing Aids

According to the Better Hearing Institute (BHI) Behind-theEar (BTE) hearing aids often demonstrate greater problems with moisture than in-the-ear (ITE) hearing aids [2]. BHI noted moisture is difficult to observe and not always easy to diagnose as the cause of hearing aid failure. As public awareness of hearing loss increases, research evaluating moisture and corrosion should additionally be mo...

متن کامل

A single-microphone-based self-adaptive filter of noise from speech and its performance evaluation.

This paper discusses a single-microphone-based self-adaptive filter of environmental noise from speech. This filter, based on the work of Graupe (3) and of Graupe and Causey (4), has been incorporated in standard in-the-ear (ITE) and in behind-the-ear (BTE) hearing aids by several hearing aid manufacturers. Intelligibility tests by the authors and by independent researchers are presented in thi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Academy of Audiology

دوره 1 3  شماره 

صفحات  -

تاریخ انتشار 1990