Use of alternative reference standards and exempted species to evaluate the performance of the Vitek 2 GP67 cefoxitin/oxacillin screen for coagulase-negative staphylococci.

نویسندگان

  • W Michael Dunne
  • Rita Griffith
  • Virginia Shortridge
چکیده

We find it most interesting in the report of Johnson et al. (1) that Staphylococcus saprophyticus strains, which comprised the second most frequent representative of their collection of coagulase-negative staphylococci (CoNS), were included in all upfront calculations of the performance of the Vitek GP67 cefoxitin/ oxacillin screen for the detection of methicillin-resistant CoNS (see the abstract and Tables 1 and 2 in reference 1). This is despite the specific limitation taken by bioMérieux for this species with the cefoxitin screen test. Johnson et al. eventually provide corrected calculations excluding S. saprophyticus in the last paragraph of the results section, and indeed they note this limitation in Materials and Methods. From the standpoint of the reader, this presentation of data is somewhat misleading. Further, the statement in the initial paragraph of the discussion section stating that the Vitek cefoxitin screen does not meet FDA requirements is perplexing – especially considering that the reference standard required for the regulatory submission to the FDA was the cefoxitin disk test and not PCR for mecA. In fact, the submission data did meet FDA guidelines for performance using CoNS (201 challenge and clinical isolates, 11 species, three sites). From these data, it was recognized that this test tended to call more S. saprophyticus isolates resistant than did the cefoxitin disk reference method. Therefore, a limitation for S. saprophyticus was taken for the product, and customers were instructed to test all cefoxitin screen-positive S. saprophyticus strains with an alternate method before reporting. We appreciate that different strain collections from various geographic locations will likely generate variable results. However, it is difficult to draw comparisons from two disparate studies and conclude that the product does not meet FDA requirements, particularly when the comparison is to a different reference method.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of methicillin-resistant coagulase-negative staphylococci by the Vitek 2 system.

The accurate performance of the Vitek 2 GP67 card for detecting methicillin-resistant coagulase-negative staphylococci (CoNS) is not known. We prospectively determined the ability of the Vitek 2 GP67 card to accurately detect methicillin-resistant CoNS, with mecA PCR results used as the gold standard for a 4-month period in 2012. Included in the study were 240 consecutively collected nonduplica...

متن کامل

Performance of different phenotypic tests in detecting mecA mediated methicillin resistance in Coagulase negative staphylococci (CoNS)

Accurate detection of methicillin resistance (MR) in coagulase negative staphylococci (CoNS) is of utmost importance as infections due to CoNS are on the rise. Various phenotypic methods have been described for detecting mecA mediated MR with varying performance characteristics. The present study was designed to evaluate the performance of oxacillin and cefoxitin disc diffusion / MIC test and o...

متن کامل

Evaluation of oxacillin and cefoxitin disks for detection of resistance in coagulase negative staphylococci.

Coagulase-negative Staphylococcus spp. was considered nonpathogenic until the emergence of multiresistance and the demonstration of their participation as infectious agents. In Brazil, oxacillin resistance may be present in over 80% of isolates, and the Clinical and Laboratory Standards Institute standardized a disk-diffusion method to predict this resistance in Staphylococcus. The aim of this ...

متن کامل

Comparison of ATB staph, rapid ATB staph, Vitek, and E-test methods for detection of oxacillin heteroresistance in staphylococci possessing mecA.

The performance characteristics of the E-test (AB Biodisk, Solna, Sweden), the ATB Staph, the Rapid ATB Staph, and the Vitek GPS-503 card (bioMérieux, La Balme Les Grottes, France) methods for the detection of oxacillin resistance in a collection of staphylococci with a high proportion of troublesome strains were evaluated. Sixty-four Staphylococcus aureus strains and 76 coagulase-negative stap...

متن کامل

Differentiationo Methicillin-Resistant and Methicillin-Susceptible Staphylococcus Aureus and Coagulase-Negative Staphylococci using Cefoxitin

Detection of the mecA gene or PBP2a is considered the gold standard for detecting mecA-mediated methicillin resistance in staphylococci. Among available phenotypic methods, the Clinical and Laboratory Standards Institute (CLSI) has introduced the cefoxitin disk diffusion (DD) test for predicting the presence of mecA in S. aureus and CoNS, which is preferred over the oxacillin DD test. Automated...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 53 1  شماره 

صفحات  -

تاریخ انتشار 2015