Comparison of fecal crude protein and fecal near-infrared reflectance spectroscopy to predict digestibility of fresh grass consumed by sheep.

نویسندگان

  • A Fanchone
  • H Archimède
  • M Boval
چکیده

Organic matter digestibility (OMD), an essential criterion for the evaluation of the nutrition of ruminants, cannot be measured easily at pasture. Therefore, the objective of this study was to test and compare 2 methods of OMD prediction based on the fecal CP content (CPf) or near infrared reflectance spectroscopy (NIRS) applied to feces. First, published equations derived from fecal N (Eq. 1(CP), n = 40) and from fecal NIRS (Eq. 1(NIRS), n = 84) were used to predict OMD of an independent validation data set from which in vivo OMD, ranging from 58 to 74%, was measured for 4 regrowth stages of Digitaria decumbens. Second, to establish equations usable in grazing situations and to improve the efficiency of the predictions, new equations were calculated from a large data set (n = 174) using CPf (Eq. 2(CP)) or fecal NIRS (Eq. 2(NIRS)). By applying the CPf method, Eq. 2(CPf) (OMD, % = 88.4 - 263.9/CPf, % of OM; residual SD = 2.92, r(2) = 0.63) showed similar statistical parameters (P < 0.01) when compared with Eq. 1(CP) (OMD, % = 86.6 - 266.2/CPf, % of OM; residual SD = 2.95, r(2) = 0.79). When using fecal NIRS, Eq. 2(NIRS) showed decreased SE of calibration (SEC = 1.48) and of cross-validation (SECV = 1.75) and greater coefficient of determination of cross-validation (R(2)(CV) = 0.85) than the previously published Eq. 1(NIRS) (SEC = 1.78, SECV = 2.02, R(2)(CV) = 0.77). The validation of the 4 equations on the validation data set was satisfactory overall with an average difference between the predicted and the observed OMD ranging from 0.98 to 2.79 percentage units. The Eq. 2(NIRS) was nevertheless the most precise with a decreased residual SD of 2.53 and also the most accurate, because the SD of the average difference between predicted and observed OMD was the lowest. Therefore, fecal NIRS provided the most reliable estimates of OMD and is thus a useful tool to predict OMD at pasture. However, an adequate number of reference data are required to establish good calibration. Indeed, better calibration statistics were obtained by increasing the data set from 84 (Eq. 1(NIRS)) to 174 (Eq. 2(NIRS)). In contrast, using fecal N on a set of 84 or 174 points did not improve the prediction. Both methods are useful for predicting OMD at pasture in certain circumstances, using fecal NIRS when a large data set (n = 84 and n = 174) is available and fecal CP with smaller data sets (n = 40).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Protein and Moisture in Fishmeal by Near-Infrared Reflectance Spectroscopy and Multivariate Regression Based on Partial Least Squares

The potential of Near Infrared Reflectance Spectroscopy (NIRS) as a fast method to predict the Crude Protein (CP) and Moisture (M) content in fishmeal by scanning spectra between 1000 and 2500 nm using multivariate regression technique based on Partial Least Squares (PLS) was evaluated. The coefficient of determination in calibration (R2C) and Standard Error of Calibra...

متن کامل

Estimating Nitrogen and Acid Detergent Fiber Contents of Grass Species using Near Infrared Reflectance Spectroscopy (NIRS)

Chemical assessments of forage clearly determine the forage quality; however, traditional methods of analysis are somehow time consuming, costly, and technically demanding. Near Infrared Reflectance Spectroscopy (NIRS) has been reported as a method for evaluating chemical composition of agriculture products, food, and forage and has several advantages over chemical analyses such as conducting c...

متن کامل

Fecal NIRS prediction of dietary protein percentage and in vitro dry matter digestibility in diets ingested by goats in Mediterranean scrubland

A method to elucidate the nutritional value of goats’ diets in ligneous environments is needed. Near infrared spectroscopy (NIRS) can be applied to fecal material to establish statistical relationships between the reflectance of fecal samples in the near infrared region and the diets consumed. We tested fecal NIRS for the prediction of dietary crude protein content (CP) and in vitro dry matter ...

متن کامل

Technical note: Use of near-infrared reflectance spectroscopy to predict intake and digestibility in bulls and steers.

Multiple fecal samples were collected from growing Angus bulls (264 to 419 kg of BW, 3.0 to 11.4 kg/d of DMI) to predict DMI of a corn-silage-based diet. Contemporaneous digestion trials were conducted with the same diet in 12 steers in yr 1 to 3 and bulls in yr 4. Near-infrared spectra from fecal samples (n = 730 from 282 growing bulls, n = 240 from 36 steers and 12 bulls for digestion trials)...

متن کامل

Variability of cow - specific organic matter digestibility within lactation and across cows based on NIRS scans from fecal samples

Near infrared reflectance spectroscopy (NIRS) provides an opportunity to measure cowspecific organic matter digestibility (OMD) from fecal samples. In this study individual digestibility measurements from a trial with 47 cows were investigated. Digestibility increased when lactation progressed. The repeatability estimates between different lactation stages were low which suggests that several f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of animal science

دوره 87 1  شماره 

صفحات  -

تاریخ انتشار 2009