Differences etween Negative and Positive Corona Discharge Fed by CO2 in Ozone Production
نویسندگان
چکیده
The efficiency of ozone generation in DC corona discharge fed by carbon dioxide has been studied. A simple coaxial system of electrodes has been used for generation of both negative and positive corona discharge in flowing gas. The ozone concentration has been measured on the outlet of the reactor by UV absorption spectroscopy methods. Ozone generation in the negative corona discharge was found to be more efficient than in positive corona.
منابع مشابه
The Effect of Electrode Material on Ozone Production in Negative Corona Discharge Fed by Oxygen and Carbon Dioxide
The negative corona discharge has been generated in flowing oxygen and carbon dioxide. Electrodes in the reactor were in coaxial geometry. The inner (wire) electrode was made of molybdenum and the outer electrode was made of stainless steel, aluminium or brass. The negative corona discharge has been generated in flowing pure oxygen and carbon dioxide at atmospheric pressure and ambient temperat...
متن کاملMass spectrometric analysis of small negative ions (e/m < 100) produced by Trichel pulse negative corona discharge fed by ozonised air
Mass spectrometric analysis of small negative ions (e/m < 100) produced by DC negative corona discharge in ozonised wet air both in flow and flow-stopped regimes was conducted at pressure of 30 kPa. The point-to-plain electrode system has been used. The yield of individual ions is strongly affected by trace concentrations of ozone in both regimes. Ozone concentration greater than 25 ppm is suff...
متن کاملInactivation of bacteria using dc corona discharge: role of ions and humidity.
Here we present the results of an experimental study of the effect of ions produced in a dc corona discharge on inactivation of bacteria on the surface of agarose gel. Both positive and negative corona discharges in various gases at different humidities were studied. The measurements in air, O(2), N(2), Ar and He mixtures show that there is no inactivation in pure N(2), pure O(2) and an N(2)-H(...
متن کاملEffect of Corona Discharge on Onions in a Commercial Storage
Onions can be stored for six months or longer at recommended storage conditions of 0° C and 6570% relatively humidity (RH) (Hardenburg, et al., 1986). Under low humidity storage, onions can suffer substantial moisture loss resulting in reduced salable product. However, under high humidity, onions may develop blue and black mold as well as soft rot caused by spp, , and , respectively. Corona dis...
متن کاملOxidation of gaseous elemental mercury in a high voltage discharge reactor.
Effects of the voltage waveform, discharge tooth wheel number and CO2/NO/SO2 concentration in the simulated flue gas on Hgo oxidation were investigated using a link tooth wheel-cylinder reactor energized by different high voltage power supplies. Negative DC discharge induced more ozone production and a higher Hg0 oxidation efficiency than positive DC discharge and 12 kHz AC discharge. The disch...