Optimization of Single-Sensor Two-State Hot-Wire Anemometer Transmission Bandwidth
نویسنده
چکیده
Hot-wire anemometric measurements of non-isothermal flows require the use of thermal compensation or correction circuitry. One possible solution is a two-state hot-wire anemometer that uses the cyclically changing heating level of a single sensor. The area in which flow velocity and fluid temperature can be measured is limited by the dimensions of the sensor's active element. The system is designed to measure flows characterized by high velocity and temperature gradients, although its transmission bandwidth is very limited. In this study, we propose a method to optimize the two-state hot-wire anemometer transmission bandwidth. The method is based on the use of a specialized constanttemperature system together with variable dynamic parameters. It is also based on a suitable measurement cycle paradigm. Analysis of the method was undertaken using model testing. Our results reveal a possible significant broadening of the two-state hot-wire anemometer's transmission bandwidth.
منابع مشابه
Development and Characterization of Surface Micromachined, Out-of-Plane Hot-Wire Anemometer
In this paper, we report the development of a new type of hot-wire anemometer (HWA) realized by using a microfabrication process that combines surface micromachining and an efficient three-dimensional assembly technique. The HWA uses a thermal element (hot wire) that is made of Pt/Ni/Pt film with a measured temperature coefficient of resistance (TCR) of 2400 ppm/ C. The thermal element is eleva...
متن کاملTransient thermal response of a hot-wire anemometer
The ability of a thermal anemometry system to accurately measure unsteady fluid velocity depends on the electrical control system as well as the thermal properties of the sensor. The present work is a numerical study of the thermal transient response of a hot-wire. A conventional constant temperature anemometer with an ideal feedback amplifier as well as a pulse width modulated system were used...
متن کاملTwo-Dimensional Micromachined Flow Sensor Array for Fluid Mechanics Studies
We discuss two types of micromachined flow sensors realized by using novel microfabrication processes—a hot-wire anemometer ~based on thermal transfer! and a biologically inspired flow sensor ~based on momentum transfer!. Both sensors are enabled by a new, efficient three-dimensional assembly technique called the plastic deformation magnetic assembly method. The sensors can be packaged in high-...
متن کاملAn Adaptive Response Compensation Technique for the Constant-Current Hot-Wire Anemometer
An adaptive response compensation technique has been proposed to compensate for the response lag of the constant-current hot-wire anemometer (CCA) by taking advantage of digital signal processing technology. First, we have developed a simple response compensation scheme based on a precise theoretical expression for the frequency response of the CCA (Kaifuku et al. 2010, 2011), and verified its ...
متن کاملAll-optical fiber anemometer based on laser heated fiber Bragg gratings.
A fiber-optic anemometer based on fiber Bragg gratings (FBGs) is presented. A short section of cobalt-doped fiber was utilized to make a fiber-based "hot wire" for wind speed measurement. Fiber Bragg gratings (FBGs) were fabricated in the cobalt-doped fiber using 193 nm laser pulses to serve as localized temperature sensors. A miniature all-optical fiber anemometer is constructed by using two F...
متن کامل