Interactive Mr-guided Percutaneous Nephrostomy Using an Open 1t Mr-scanner: First Experience in 15 Patients

نویسندگان

  • F. Fischbach
  • M. Porsch
  • J. Bunke
  • M. Pech
  • O. Dudeck
  • U-B. Liehr
  • J. Ricke
چکیده

INTRODUCTION Usually percutaneous nephrostomy is performed under sonographic guidance in a fluoroscopy suite. Although MR provides detailed images of the upper urinary tract (1,2), there still exist only very preliminary results that have been reported about MR -guided percutaneous nephrostomy (3,4). When sonographic guidance is not possible due to e.g. severe obesity, overlying intestinal gas, or parapelvic cysts MR guidance could be an alternative approach in these cases. The purpose of this study was to assess the safety and feasibility of MR-guided percutaneous nephrostomy (MRPCN) using an open 1.0T scanner and MR fluoroscopic imaging. MATERIAL AND METHODS MR guidance and monitoring was performed using a 1.0T open system with vertical field orientation (Panorama, Philips, Best, The Netherlands). A belt-shaped 21-cm-diameter loop receive-only coil was used for signal reception and placed in the region of the kidneys. Imaging and the percutaneous puncture of the collecting system were performed in a prone/semilateral position of the patient. An in-room RF-shielded liquid crystal monitor was used for image display at the side of the magnet analogous to a fluoroscopy monitor. The equipment included an 18-gauge MR-compatible titanium puncture needle, a nitinol guide wire, different tract dilatators and a 7.6F nephrostoma-catheter. MR guidance was performed in an interactive continuous scan mode providing 1 image per second with a fluoroscopic fast T2-w single shot 2D TSE sequence (TR/TE 1000/100 ms, FOV 300x300 mm, matrix 2.0x2.4 mm, slice thickness 8 mm) in two orthogonal planes was used to guide the insertion of the needle into a predetermined calyx in freehand technique. The skin entry site was defined with finger pointing. When the needle was placed deeply in the pelvic system the patient was moved out of the magnet to insert the catheter via Seldinger technique. Finally the correct placement of the device within the urinary collecting system was confirmed by fat saturated breath hold T1w GRE sequence in coronal orientation after injection of diluted Gd-DTPA into the collecting system (FFE TR/TE 5.4/2.6 ms; flip 12°, FOV 300x300 mm, matrix 1.1x1.3 mm, slice thickness 3 mm). RESULTS So far we performed 22 MR-guided nephrostomies in 15 patients. The guiding procedure could be completely performed inside the magnet in all cases With the help of fluoroscopic interactive continuous imaging in two orthogonal planes, the puncture needle was safely directed into the target calyx. Even slight deviations of the needle from the intended path were detected in both MR image planes, allowing for immediate readjustment of the needle position in free hand technique (fig. 1). All procedures resulted in successful puncture of the calyx. No complications occurred. Under the experimental conditions of the study, the time for planning and placement of the nephrostoma lasted approx. 30 minutes. DISCUSSION The advantages of MR fluoroscopy including missing radiation, high tissue contrast, multiplanar imaging and the availability of open high field systems giving good access to the patient and sufficient SNR should encourage broadening the indications for MR-guided interventions. MR-guided percutaneous nephrostomy can be performed in a routine setting. This is especially of interest in patients not suited for sonographic guidance. REFERENCES (1) Roy C, Saussine C, Jahn C, et al. Evaluation of RARE-MR urography in the assessment of ureterohydronephrosis. J Comput Assist Tomogr 1994; 18:601-608; (2) Regan F, Bohlman ME, Khazan R, Rodriguez R, Schultze-Haakh H. MR urography using HASTE imaging in the assessment of ureteric obstruction. AJR 1996; 167:1115-1120, (3) Hagspiel KD, Kandarpa K, Silverman SG. Interactive MR-guided percutaneous nephrostomy. JMRI 1998; 8:1319-1322, (4) Kariniemi J, Sequeiros RB, Ojala R, Tervonen O. MRI-guided percutaneous nephrostomy: a feasibility study. Eur Radiol. 2009 May;19(5):1296-301.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Functional MR imaging on an open 1T MR imaging system: exploiting the advantages of an open MR imaging system for functional MR imaging.

BACKGROUND AND PURPOSE Open MR imaging scanners are designed for imaging of specific patient groups that cannot be routinely scanned with conventional MR imaging scanners (eg, patients with obesity and claustrophobia). This study aims to determine whether BOLD sensitivity on an open 1T scanner is adequate for fMRI for diagnostic and research purposes by directly comparing fMRI results with a st...

متن کامل

MR-guided percutaneous nephrostomy of the nondilated upper urinary tract in a porcine model.

OBJECTIVE The purpose of this study was to assess the safety and feasibility of MR-guided percutaneous nephrostomy of the nondilated contrast-enhanced upper urinary tract in a porcine model. SUBJECTS AND METHODS Six MR-guided percutaneous nephrostomies of the nondilated upper urinary tract were performed in four domestic farm pigs (body weight range, 20-25 kg) using a 0.2-T system. Ten minute...

متن کامل

Water-enhanced antegrade MR pyelography in pregnancy: a novel radiation-free approach

Our aim was to determine if water-enhanced antegrade magnetic resonance (MR) pyelography can be an alternative to conventional antegrade pyelography in pregnant patients who require percutaneous nephrostomy placement for urosepsis and/or obstructive uropathy. The pregnant patient was placed supine in a 1.5-T MRI scanner seven days after percutaneous nephrostomy placement using ultrasound. Seria...

متن کامل

Feasibility of MR guided direct arthrography

S. Wakeley, M. J. Graves, P. Bearcroft, R. T. Black, E. van Rooyen, D. J. Lomas Radiology, University of Cambridge & Addenbrooke's Hospital, Cambridge, United Kingdom, Medical Physics, University of Cambridge & Addenbrooke's Hospital, Cambridge, United Kingdom Introduction Direct MR arthrography is increasingly the preferred imaging investigation for diagnosing subtle intra-articular joint path...

متن کامل

Initial clinical experience with a robotic assistance system for liver biopsies in a diagnostic 1.5T MR scanner

Introduction/Purpose Freehand MR-guided biopsies in a closed-bore MRI scanner are typically performed by iterative cycles of visual targeting, manual instrument feed (outside the bore) and verification of the actual position with MR imaging (inside the bore) [1]. Based on the potential needle offset seen on the MR image, the physician uses a mental representation of the 3D geometry to repositio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009