aspects o f integrated high Tc de - SQUID magnetometer fabrication 707

نویسندگان

  • J. Flokstra
  • H. Rogalla
چکیده

An integrated high Tc de-SQUID magnetometer is being developed. It has in total 10 layers of five different materials. Various materials aspects of the fabrication process will be discussed, especially the smoothness of the films and the techniques to obtain smooth edges. Cross-overs and superconducting window 9contacts were fabricated. The critical temperature of the window-contact is 84K (jc(77K)=2.10"A/cm -) and the resistivity of the insulating SrTiO 3 layer in the cross-over is 6-10 f~cm at 77K. The complete coil often shows a small resistive component down to about 50K. Ramp type and bi-epitaxial grain boundary de-SQUIDs show voltage modulation up to 65K and 79K, respectively. Efforts to fabricate an integrated high T e de-SQUID magnetometer will be discussed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low-field magnetic resonance imaging with a high-Tc dc superconducting quantum interference device

A spectrometer incorporating a high transition temperature dc superconducting quantum interference device ~SQUID! is used to obtain nuclear magnetic resonance signals from protons in mineral oil at room temperature in fields up to 3 mT. The spatial separation between the SQUID magnetometer at 77 K and the sample at room temperature is less than 1 mm. At 2 mT, the signal is easily resolved in a ...

متن کامل

Superconducting Quantum Interference Device: The Most Sensitive Detector of Magnetic Flux

SQUIDs are the most sensitive devices in detecting the magnetic flux. The devices have been used to detect small magnetic field, current, voltage, inductance and magnetic susceptibility etc. In this work, we reported studies and applications of high-Tc YBa2Cu3Oy SQUIDs. Two main techniques of depositing YBCO thin films are described; the characteristic of thin film and high-Tc SQUID are address...

متن کامل

Ultimate limitation of the SQUID magnetometer

The Superconducting QUantum Interference Device is used to detect weak biomagnetic signals since in the early seventies. In that time the measurement was based on point contact rf SQUIDs operated at 20 MHz, with to a flux noise of the order of 10-4 Φ 0/ √Hz . After finding methods to fabricate reliable thin-film devices, the dc SQUIDs started gradually replace the rf SQUIDs. [1] The dc SQUID wi...

متن کامل

Analysis of MCG with spatial filter method

Magnetocardiogram (MCG) mapping is a new promising non-invasive tool for obtaining functional information concerning the electrical activities of the heart. Since MCG was first measured by Baule and McFee[1], the MCG has been studied worldwide. In particular, it is known that Cohen and his co-workers measured the MCG by use of a SQUID inside a magnetically shielded room[2] and the technique has...

متن کامل

Four layer monolithic integrated high T, dc SQUID magnetometer

Y13aZCus0,-, based monolithic integrated dc SQUID magnetometers, consisting of a dc SQUID integrated with a flux transformer on a single bicrystalline substrate, have been fabricated and characterized. The devices consist of four layers, including two superconducting layers, and first realizations operate up to 73 K. A maximum voltage modulation of 32 ,u,V is observed at 40 K. A field sensitivi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002