Carotid stenosis by digital subtraction angiography: reproducibility of the European Carotid Surgery Trial and the North American Symptomatic Carotid Endarterectomy Trial measurement methods and visual interpretation.

نویسندگان

  • R Vanninen
  • H Manninen
  • K Koivisto
  • H Tulla
  • K Partanen
  • M Puranen
چکیده

PURPOSE To evaluate different carotid stenosis estimation methods with digital subtraction angiography. METHODS We assessed the intraobserver reproducibilty and interobserver variability of visual interpretation and the measurement methods used by the European Carotid Surgery Trial and the North American Symptomatic Carotid Endarterectomy Trial. Angiographic stenosis measurements according to both criteria were performed twice by a radiologist, a neurologist, and a vascular surgeon. Eighty bifurcations of consecutive symptomatic patients underwent 480 pairs of measurements. In addition, four radiologists estimated the stenoses visually. RESULTS Intraobserver consistency was slightly better by the European (kappa, 0.86 to 0.94) than by the North American (kappa, 0.68 to 0.91) trial criteria or by visual interpretation (kappa, 0.79 to 0.81). No significant interobserver variability was found, except in the subgroup of mild stenoses by the North American Trial criteria. By kappa statistic, the interobserver agreement was excellent by the European trial method (kappa, 0.72 to 0.86), good by the North American trial method (kappa, 0.59 to 0.77), and good to excellent by visual evaluation (kappa, 0.68 to 0.88). The visual estimation agreed more closely with the European (kappa, 0.73 to 0.92) than with the North American trial (kappa, 0.55 to 0.74) criteria measurements. CONCLUSIONS All three methods have good reproducibility in digital subtraction angiography. Interobserver differences become more important in the estimation of mild stenosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lumen reduction measurements of the internal carotid artery before and after Levovist enhancement: reproducibility and agreement with angiography.

Our aim was to assess reproducibility of three different lumen reduction measuring methods--North American Symptomatic Carotid Endarterectomy Trial, European Carotid Surgery Trial, and common carotid--using power Doppler and color Doppler sonography before and after Levovist enhancement. We included 20 symptomatic patients with mild or severe carotid disease. North American Symptomatic Carotid ...

متن کامل

Internal carotid artery stenosis measurement: comparison of 3D computed rotational angiography and conventional digital subtraction angiography.

BACKGROUND AND PURPOSE Clinical trials have shown that carotid endarterectomy reduces stroke risk in symptomatic individuals with severe internal carotid artery (ICA) stenosis. As a result of these trials, digital subtraction angiography (DSA) became a standard of reference for ICA stenosis diagnosis. Newer 3D techniques provide a larger number of views than DSA, which may influence the estimat...

متن کامل

Measuring carotid stenosis on contrast-enhanced magnetic resonance angiography: diagnostic performance and reproducibility of 3 different methods.

BACKGROUND AND PURPOSE The aim of this study was to compare diagnostic performance and reproducibility of 3 different methods of quantifying stenosis on contrast-enhanced magnetic resonance angiography (CEMRA), with intra-arterial digital subtraction angiography (DSA) as the reference standard. METHODS 167 symptomatic patients scheduled for DSA, after screening Doppler ultrasound, were prospe...

متن کامل

Multi-detector row CT angiography in the assessment of carotid artery disease in symptomatic patients: comparison with rotational angiography and digital subtraction angiography.

BACKGROUND AND PURPOSE Compared with the single-detector technique, multi-detector row CT angiography permits larger anatomic coverage that includes both the epiaortic and entire carotid circulations. We evaluated the accuracy of multi-detector row CT angiography by using multiplanar reformation (MPR) for measuring carotid artery diameters compared with that of rotational angiography. We also e...

متن کامل

Prognostic Value and Reproducibility of Measurements of Carotid Stenosis A Comparison of Three Methods on 1001 Angiograms

Background and Purpose The use of three methods of measuring carotid stenosis, which produce different values on the same angiograms, has caused confusion and reduced the generalizability of the results of research. If the results of future studies are to be properly applied to clinical practice, and if noninvasive methods of imaging are to be properly validated against angiography, a single, s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 15 9  شماره 

صفحات  -

تاریخ انتشار 1994