The effects of luminance on FPL and VEP acuity in human infants.
نویسندگان
چکیده
Grating acuity was measured in 16-week-old human infants. Three measurement techniques were used: forced-choice preferential-looking (FPL), and two visual-evoked-potential (VEP) techniques. The stimuli were counterphase flickering sinewave gratings with a space-average luminance of -1.0 or 2.0 log cd/m2. Slightly different luminance-dependent changes occur between FPL and VEP acuities, suggesting that some factor influences the two methods differently as stimulus luminance varies. A comparison between FPL acuities and VEP acuities within infants suggests a quantitative relationship between techniques. Infant's acuity for sinewave gratings with a space-average luminance of -2.0, -1.0, 0.0, 1.0 and 2.0 log cd/m2 was also measured using a single VEP paradigm. The results are compared to the same measurements in adults and to infant and adult ideal observers. VEP acuity in this group of infants improves by about 0.5 log units between -2.0 and 0.0 log cd/m2 and remains asymptotic between 0.0 and 2.0 log cd/m2. This result suggests that luminance-dependent changes in infant acuity cannot be fully accounted for by immaturities in the optics and photoreceptor spacing and efficiency.
منابع مشابه
Comparison of pattern VEPs and preferential-looking behavior in 3-month-old infants.
Studies of visual acuity in human infants between 1 and 6 months of age using the visual-evoked potential (VEP) and forced-choice preferential looking (FPL) have shown that acuity is one to two octaves higher by VEP estimates than by FPL estimates. In an attempt to study these differences, the authors obtained both VEP and FPL data from 26 3-month-old infants. VEP data were obtained with gratin...
متن کاملFPL and VEP measures of fusion, stereopsis and stereoacuity in normal infants
Dynamic random dot fusion, stereopsis and stereoacuity were evaluated in 149 healthy, fullterm infants, using both forced-choice preferential looking (FPL) and steady-state visual evoked potential (VEP) protocols. Few infants aged 2-3 months demonstrated fusion or stereopsis in either the FPL or VEP protocol; most infants aged 5 months and older demonstrated fusion and stereopsis in both protoc...
متن کاملInfant VEP and preferential looking acuity measured with phase alternating gratings.
Previously, infants' grating acuity was found to be temporally tuned, but adults' grating acuity was not. In infants, acuity was higher for gratings phase alternating at 7.5 and 14 reversals/sec than for stationary gratings and gratings alternating at 2.5 or 23 reversals/sec. Also, when preferential looking (PL) and visually evoked potential (VEP) acuity were estimated with phase alternating gr...
متن کاملDoes a front-end nonlinearity confound VEP acuity measures in human infants?
The visual evoked potential is commonly used to estimate visual acuity in infants. The stimulus used is temporally modulated in order to drive the cortical response. Here it is proposed that distortion products generated by a front-end nonlinearity may contaminate the acuity estimate. Specifically, the nonlinearity might convert temporal modulation of a high spatial frequency grating into appar...
متن کاملDevelopment of a quantitative method to measure vision in children with chronic cortical visual impairment.
PURPOSE Cortical visual impairment (CVI) is the most common cause of bilateral vision impairment in children in Western countries. Better quantitative tools for measuring vision are needed to assess these children, to allow measurement of their visual deficit, and to monitor their response to treatment and rehabilitation. The author performed a series of experiments to assess the use of the swe...