Estimation of operators' fatigue using optical methods for determination of pupil activity.

نویسندگان

  • Krzysztof Różanowski
  • Michał Bernat
  • Agnieszka Kamińska
چکیده

INTRODUCTION The purpose of this study was to develop and initially validate an objective, yet quick, method for assessment of human fatigue. This aim can be achieved by the use of an optical, non-contact method of analysis of pupil activity. The study involved 2 phenomena typical for the behavior of the human pupil: pupillary reflex and pupillary movements. The 1st phenomenon is related to the pupillary light reflex (PLR), which presents the results of physiological adaptation mechanisms of the human eye. The pupillary unrest index (PUI) is an additional parameter referring to the tendency for instability of the pupil. MATERIAL AND METHODS Indicators of these 2 mechanisms were assessed under the same experimental laboratory conditions. Assessment was conducted on a group of volunteers (N = 10) during 4 controlled series of measurements performed at night. Pupillary reflex parameters associated with PLR and pupillary unrest index (PUI) were recorded using F²D Fit-For-Duty, a commercially available system made by AMTech Pupilknowlogy GmbH. Baseline pupil diameter, oscillations, reflex latency, maximum reaction time, pupil constriction time, pupil dilation time, and constriction amplitude were recorded. RESULTS As a result of the study, we were able to demonstrate correlation and confirm the usefulness of PLR and PST methods in the assessment of sleep deprivation. Parameters of PLR that may indicate human fatigue were identified. The effect of light impulse sequences on the dynamics of pupillary reflex and the relationship between PUI (pupillary unrest index) measurement duration and sleepiness assessment validity, were assessed. CONCLUSIONS The results of the pilot studies were sufficient to develop minimum requirements for a PLR sensor that would be capable of estimating the level of fatigue with accuracy of a PUI method, but at a 5 times faster rate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating the Visual Fatigue in VDT Operators in the Banks of Qasr-e Shirin (Kermanshah-Iran)

Background & Aims of the Study: Due to the increasing use of computers in the administrative and social structure of Iran, it seems that, in the near future, eye and body symptoms caused by computer work will become one of the most important health issues in our society, and threaten the health of the workforce and consequently, lead to significant financial and industrial losses. The aim of th...

متن کامل

Modeling of measurement error in refractive index determination of fuel cell using neural network and genetic algorithm

Abstract: In this paper, a method for determination of refractive index in membrane of fuel cell on basis of three-longitudinal-mode laser heterodyne interferometer is presented. The optical path difference between the target and reference paths is fixed and phase shift is then calculated in terms of refractive index shift. The measurement accuracy of this system is limited by nonlinearity erro...

متن کامل

مقایسه موردی روش‌های مختلف تعیین تنش هات‌اسپات‌ در جزئیات سازه کشتی

Fatigue analysis and estimation of safe life of structures that are subjected to cyclic loadings, such as ships and offshore structures is one of the most important steps of structural design. Fatigue failure in the form of crack will start from details and propagate in structure. In steel structures these cracks will started from welds. Most of the methods for fatigue life assessment in welded...

متن کامل

بررسی پایایی و تکرار پذیری دستگاه Spectral domain optical coherence tomography در اندازه گیری ضخامت ماکولا در چشمهای طبیعی قبل و بعد از گشاد کردن مردمک

Background: optical coherence tomography is one of the most valuable imaging techniques in the evaluation of macula. Objective: to investigate the repeatability and reproducibility of OCT  in measuring the macular thickness in normal eyes before and after pupil dilation. Methods: A total of 44 eyes were enrolled. All subjects underwent macular thickness measurement using the Cirrus SD-OCT ma...

متن کامل

Determination of 40K concentration in milk samples consumed in Tehran-Iran and estimation of its annual effective dose

Background: Since 40K is the most important natural radionuclide in the environment, its concentration was measured for all milk and milk powder samples consumed in Tehran-Iran. Milk was chosen, since because it is a reliable indicator of the general population intake of certain radionuclide, and many environmental programs have been applied for its safety. Materials and Methods: Measu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of occupational medicine and environmental health

دوره 28 2  شماره 

صفحات  -

تاریخ انتشار 2015