Metal-oxide surge arrester model for fast transient simulations
نویسندگان
چکیده
Metal-oxide surge arresters have dynamic characteristics that are significant for overvoltage coordination studies involving fast front surges. Several models with acceptable accuracy have been proposed to simulate this frequency-dependent behavior. Difficulties arise in the calculation and adjustment of the model parameters: in some cases iterative procedures are required, in others the necessary data are not reported on manufacturers’ datasheets. A simplified model for zinc oxide surge arresters has already been developed, on the basis of the frequencydependent model recommended by the IEEE WG.3.4.11. In this paper, a different, also straightforward approach, for the generation of the IEEE model parameters from published manufacturer’s data, is presented. The model was verified for several medium voltage arresters from different manufacturers. The simulations were performed with the Alternative Transient Program (ATP) and the results were compared with both the data reported on the manufacturer’s catalogue and experimental data acquired in the high voltage laboratory. For a fast front current surges with front times of up to 1 μs, the model has an acceptable voltage response accuracy of about 1.5%.
منابع مشابه
Simulation of metal oxide surge arrester dynamic behavior under fast transients
Data on characteristics of metal-oxide surge arresters indicates that for fast front surges, those with rise times less than 8μs, the peak of the voltage wave occurs before the peak of the current wave and the residual voltage across the arrester increases as the time to crest of the arrester discharge current decreases. Several models have been proposed to simulate this frequency-dependent cha...
متن کاملEstimation of parameters of metal-oxide surge arrester models using Big Bang-Big Crunch and Hybrid Big Bang-Big Crunch algorithms
Metal oxide surge arrester accurate modeling and its parameter identification are very important for insulation coordination studies, arrester allocation and system reliability. Since quality and reliability of lightning performance studies can be improved with the more efficient representation of the arresters´ dynamic behavior. In this paper, Big Bang – Big Crunch and Hybrid Big Bang – Big Cr...
متن کاملImpacts of New Suggested Ferroresonance Limiter on the Stability Domain of Ferroresonance Modes in Power Transformers Considering Metal Oxide Surge Arrester Effect
this work studies the effect of neutral earth resistance on the controlling ferroresonance oscillation in the power transformer including MOV surge arrester. A simple case of ferroresonance circuit in a three phase transformer is used to show this phenomenon and the three-phase transformer core structures including nonlinear core losses are discussed. The effect of MOV surge arrester and neutra...
متن کاملCondition Assessment of Metal Oxide Surge Arrester Based on Multi-Layer SVM Classifier
This paper introduces the indicators for surge arrester condition assessment based on the leakage current analysis. Maximum amplitude of fundamental harmonic of the resistive leakage current, maximum amplitude of third harmonic of the resistive leakage current and maximum amplitude of fundamental harmonic of the capacitive leakage current were used as indicators for surge arrester condition mon...
متن کاملPerformance of Surge Arrester to Multiple Lightning Strokes on Nearby Distribution Transformer
Overhead distribution lines are prone to lightning overvoltages due to their configurations and characteristics. Metal Oxide Varistor (MOVs) arresters for many years have proven to be more advantageous than others arresters in lightning surge protection; therefore it is worthwhile to continually assess the behavior and performance of these arresters to different kind of overvoltages caused by l...