Evaluation of corneal flap dimensions and cut quality using the Automated Corneal Shaper microkeratome.

نویسندگان

  • A Behrens
  • B Seitz
  • A Langenbucher
  • M M Kus
  • C Rummelt
  • M Küchle
چکیده

PURPOSE To evaluate flap dimensions and cut deterioration with repeated blade use in an automated microkeratome. METHODS The Automated Corneal Shaper (Chiron-Adatomed, Munich, Germany), 160-microm plate attached, was used to make a corneal flap in 90 pig cadaver eyes, reusing blades up to five times. Flap diameter was measured by planimetry and thickness was calculated by ultrasound pachymetry. Scanning electron microscopy of stromal beds and blade cutting edges was performed to assess cut deterioration after repeated blade use. RESULTS Mean flap central thickness was 125 +/- 32 microm. Mean vertical flap diameter was 7.6 +/- 0.4 mm. No correlation was found between thickness and diameter (r = 0.15, P = .45). Progressive thinning of the flap was observed in the direction of the flap hinge. Smooth cuts (using new blades) with periodic chatter lines at the keratectomy edge and in the stromal bed were observed with scanning electron microscopy. Increasing tissue remnants on the stromal bed and decreasing cut quality occurred with repeated blade use. Blades showed larger tissue remnants, nicks, and even folds on the cutting edge proportional to the number of times blades were used. CONCLUSION Satisfactory cut quality and reproducibility were obtained after a single use of stainless steel blades in the Automated Corneal Shaper microkeratome. Cut quality was degraded dramatically by repeated use of blades.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cut edges and surface characteristics produced by different microkeratomes.

PURPOSE To determine the cutting characteristics of seven different microkeratomes and to compare the cut edges and surface characteristics of the corneas with respect to different keratome parameters, ie, blade oscillation frequencies and keratome speed. METHODS Lamellar keratectomies were performed using each microkeratome on eight freshly enucleated porcine corneas. The freshly cut corneal...

متن کامل

Lower intraoperative flap complication rate with the Hansatome microkeratome compared to the Automated Corneal Shaper.

PURPOSE The purpose of this study was to retrospectively compare the incidence of intraoperative flap complications, such as partial flaps, donut-shaped flaps, central corneal cuts, and complete caps with the Hansatome and Automated Corneal Shaper (ACS) microkeratomes. METHODS All laser in situ keratomileusis (LASIK) procedures performed by a single surgeon with the Hansatome or Automated Cor...

متن کامل

Quality assessment model of 3 different microkeratomes through confocal microscopy.

PURPOSE To study the quality of the cut created by 3 microkeratomes from 2 different generations using corneal confocal microscopy. SETTING Department of Refractive Surgery, Instituto Oftalmológico de Alicante, Alicante, Spain. METHODS Two different studies were conducted: Study 1 and Study 2. Study 1 was a prospective analysis using confocal microscopy examination data from 2 reference gro...

متن کامل

بررسی نتایج تکنیک جدید پیوند لایه ای قرنیه با استفاده از میکروکراتوم

          This study was performed to evaluate the efficacy of anterior keratoplasty    with microkeratome in the improvement of visual acuity (V.A) in superficial    corneal disorders in patients admitted to Labbfi Nezhad hospital and Tehran    Bassir Clinic .         &nbs...

متن کامل

Comparison of two microkeratome systems.

BACKGROUND Microkeratomes are currently used for keratomiluesis in situ (automated lamellar keratoplasty) for myopia and hyperopia and for laser in situ keratomileusis (LASIK). Visual and refractive complications have been reported with these refractive surgical procedures. We compared two microkeratomes in their ability to resect corneal lamellae to gain insight into possible mechanism(s) of r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 16 1  شماره 

صفحات  -

تاریخ انتشار 2000