First report of a novel abluminal groove filled biodegradable polymer rapamycin-eluting stent in de novo coronary artery disease: results of the first in man FIREHAWK trial.

نویسندگان

  • Jie Qian
  • Bo Xu
  • Alexandra J Lansky
  • Yue-jin Yang
  • Shu-bin Qiao
  • Yong-jian Wu
  • Jue Chen
  • Feng-huan Hu
  • Wei-xian Yang
  • Gary S Mintz
  • Martin B Leon
  • Run-lin Gao
چکیده

BACKGROUND Durable polymers used for first-generation drug-eluting stents (DES) potentially contribute to persistent inflammation and late DES thrombosis. We report the first in human experience with the rapamycin-eluting biodegradable polymer coated cobalt-chromium FIREHAWK stent with abluminal groove. METHODS A total of 21 patients with stable or unstable angina, or prior myocardial infarction, with single de novo native coronary stenoses < 30 mm in length in vessel sizes ranging from 2.25 to 4.0 mm were enrolled. The primary endpoint was major adverse cardiac events (MACE) at 30 days defined as the composite of cardiac death, myocardial infarction (Q and non-Q), or ischemia-driven target lesion revascularization. Secondary endpoints include device, lesion, and clinical success rates, 4-month in-stent late lumen loss by quantitative coronary angiography (QCA), proportion of uncovered or malapposed stent struts by optical coherence tomograpphy (OCT) at 4 months, and MACE at 4, 12, 24 and 36-month follow-up. RESULTS Device success was 95.7%, lesion and clinical success was 100.0%. There were no MACE events at 30 days. One patient died of non-cardiac hemorrhagic stroke 5 days after index procedure. At 4 months, in-stent late loss was (0.13 ± 0.18) mm, and complete strut coverage was 96.2% by OCT with 0.1% strut malapposition. At 4-month follow-up there was no additional MACE events, and a single target vessel (non-target lesion) revascularization. CONCLUSIONS The FIREHAWK abluminal groove biodegradable polymer rapamycin-eluting stent demonstrated feasibility, safety and efficacy in this first in human experience. OCT findings indicated excellent stent strut coverage 4 months after implantation. Larger studies are required to confirm whether the early FIREHAWK stent results translate into longer term restenosis and thrombosis benefits.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A randomised comparison of a novel abluminal groove-filled biodegradable polymer sirolimus-eluting stent with a durable polymer everolimus-eluting stent: clinical and angiographic follow-up of the TARGET I trial.

AIMS The study sought to evaluate the safety and efficacy of FIREHAWK, a novel abluminal groove-filled biodegradable polymer sirolimus-eluting stent (SES) for treating patients with single de novo coronary lesions compared with the durable polymer everolimus-eluting stent (EES) XIENCE V. METHODS AND RESULTS A total of 458 patients with single de novo native coronary lesions ≤24 mm in length a...

متن کامل

Safety and efficacy of a novel abluminal groove-filled biodegradable polymer sirolimus-eluting stent for the treatment of de novo coronary lesions: two-year results from a prospective patient-level pooled analysis of TARGET trials.

OBJECTIVES We aimed to evaluate the safety and effectiveness of the novel abluminal groove-filled biodegradable polymer-coated sirolimus-eluting FIREHAWK stent (MicroPort Medical, Shanghai, China) in a large cohort of patients. BACKGROUND Trials on the FIREHAWK stent allowing targeted sirolimus release were not individually powered to reliably estimate low-frequency safety endpoints such as s...

متن کامل

A novel paclitaxel-eluting stent with an ultrathin abluminal biodegradable polymer 9-month outcomes with the JACTAX HD stent.

OBJECTIVES The JACTAX HD trial ("JACTAX" Trial Drug Eluting Stent Trial) evaluated the safety and clinical performance of a novel JACTAX HD (Boston Scientific Corporation, Natick, Massachusetts) paclitaxel-eluting stent (PES) in de novo coronary lesions. BACKGROUND The JACTAX HD (Boston Scientific) stent consists of a pre-crimped bare-metal Liberté (Boston Scientific) stent coated on its ablu...

متن کامل

Randomized clinical trial comparing abluminal biodegradable polymer sirolimus-eluting stents with durable polymer sirolimus-eluting stents

BACKGROUND The biodegradable polymer drug-eluting stents (DES) were developed to improve vascular healing. However, further data and longer-term follow-up are needed to confirm safety and efficacy of these stents. This randomized clinical trial aimed to compare safety and efficacy of 2 sirolimus-eluting stents (SES): Cordimax-a novel abluminal biodegradable polymer SES and Cypher Select-a durab...

متن کامل

Strut coverage and vessel wall response to a new-generation paclitaxel-eluting stent with an ultrathin biodegradable abluminal polymer: Optical Coherence Tomography Drug-Eluting Stent Investigation (OCTDESI).

BACKGROUND Polymer-coated drug-eluting stents are effective in preventing restenosis but have been associated with delayed healing and incomplete strut coverage. It is unknown whether paclitaxel-eluting stents (PES) with minimal biodegradable abluminal coating enhances strut coverage while preventing neointimal hyperplasia. Using optical coherence tomography (OCT) as a primary imaging modality,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chinese medical journal

دوره 125 6  شماره 

صفحات  -

تاریخ انتشار 2012