CT-guided biopsy of pulmonary nodules: is pulmonary hemorrhage a complication or an advantage?

نویسندگان

  • Massimo De Filippo
  • Luca Saba
  • Mario Silva
  • Raffaella Zagaria
  • Giorgio Concari
  • Rita Nizzoli
  • Cecilia Bozzetti
  • Marcello Tiseo
  • Andrea Ardizzoni
  • Stefano Lipia
  • Ilaria Paladini
  • Luca Macarini
  • Giampaolo Carrafiello
  • Luca Brunese
  • Antonio Rotondo
  • Cristina Rossi
چکیده

PURPOSE We aimed to assess the correlation between pulmonary hemorrhage and pneumothorax in computed tomography (CT)-guided transthoracic fine needle aspiration (TTFNA), particularly its possible value as protection against the development of pneumotorax. MATERIALS AND METHODS We reviewed the CT images of 538 patients (364 males and 174 females, mean age 70 years, range 36-90 years) who underwent CT-guided TTFNA of pulmonary nodules between January 2008 and September 2013. The following CT findings were assessed: pulmonary hemorrhage (type 1, along the needle track; type 2, perilesional; low-grade, ≤6 mm; high-grade, >6 mm), pneumothorax, distance between the target nodule and the pleural surface, and emphysema. RESULTS Pneumothorax occurred in 154 cases (28.6%) and pulmonary hemorrhage occurred in 144 cases (26.8%). The incidence of pneumothorax was lower in patients showing type 1 and high-grade pulmonary hemorrhage pattern. The incidence of pneumothorax in biopsies ≥30 mm from pleural surface was 26% (12/46) in cases showing this pattern, while it was 71.4% (30/42) when this pattern was not seen. Similarly, the incidence of pneumothorax in biopsies <30 mm from the pleural surface was 0% (0/28) in cases showing this hemorrhage pattern, while it was 19% (76/394) when this pattern was not seen. CONCLUSION Pulmonary hemorrhage during TTFNA is a frequent event that protects against pneumothorax. A bleeding greater than 6 mm along the needle track is associated with lower incidence of pneumothorax, especially in biopsies deeper than 3 cm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radial Probe Endobronchial Ultrasound for Peripheral Pulmonary Lesions: Initial Experience in an Indian Tertiary Healthcare Centre

Introduction : Diagnosis of peripheral pulmonary nodules is confusing; therefore, an accurate and safe lung biopsy can prevent unnecessary invasive diagnostic procedures. This study soughtto study the diagnostic yield, sensitivity, specificity, and negative and positive predictive values (NPV and PPV) of radial probe endobronchial ultrasound (EBUS)-guided biopsy for peripheral pulmonary lesions...

متن کامل

Automated classification of pulmonary nodules through a retrospective analysis of conventional CT and two-phase PET images in patients undergoing biopsy

Objective(s): Positron emission tomography/computed tomography (PET/CT) examination is commonly used for the evaluation of pulmonary nodules since it provides both anatomical and functional information. However, given the dependence of this evaluation on physician’s subjective judgment, the results could be variable. The purpose of this study was to develop an automated scheme for the classific...

متن کامل

Diagnostic Accuracy of CT-Guided Transthoracic Needle Biopsy for Solitary Pulmonary Nodules

To evaluate the diagnostic accuracy of computed tomography (CT)-guided percutaneous lung biopsy for solitary pulmonary nodules. Three hundred and eleven patients (211 males and 100 females), with a mean age of 59.6 years (range, 19-87 years), who were diagnosed with solitary pulmonary nodules and underwent CT-guided percutaneous transthoracic needle biopsy between January 2008 and January 2014 ...

متن کامل

Computed tomography-guided percutaneous cutting needle biopsy for small (≤ 20 mm) lung nodules

The goal of this study is to determine the feasibility, diagnostic accuracy, and risk factor of complications of computed tomography (CT)-guided percutaneous cutting needle biopsy (PCNB) for small lung nodules.From January 2014 to May 2015, 141 patients with small lung nodule were performed with CT-guided PCNB procedure. Data on technical success, diagnostic accuracy, and complication were coll...

متن کامل

Localization of pulmonary nodules before thoracoscopic surgery: value of percutaneous staining with methylene blue.

OBJECTIVE Video-assisted thoracic surgery (VATS) is a new procedure that makes it possible to see the intrathoracic organs and to resect pulmonary nodules without thoracotomy. Preoperative localization of small nodules that may not be visible or palpable during VATS is desirable. Percutaneous placement of spring hookwires is widely used to localize pulmonary nodules before VATS; infrequently, t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Diagnostic and interventional radiology

دوره 20 5  شماره 

صفحات  -

تاریخ انتشار 2014