Ultrashort echo time magnetization transfer (UTE-MT) imaging of cortical bone.

نویسندگان

  • Eric Y Chang
  • Won C Bae
  • Hongda Shao
  • Reni Biswas
  • Shihong Li
  • Jun Chen
  • Shantanu Patil
  • Robert Healey
  • Darryl D D'Lima
  • Christine B Chung
  • Jiang Du
چکیده

Magnetization transfer (MT) imaging is one way to indirectly assess pools of protons with fast transverse relaxation. However, conventional MT imaging sequences are not applicable to short T2 tissues such as cortical bone. Ultrashort echo time (UTE) sequences with TE values as low as 8 µs can detect signals from different water components in cortical bone. In this study we aim to evaluate two-dimensional UTE-MT imaging of cortical bone and its application in assessing cortical bone porosity as measured by micro-computed tomography (μCT) and biomechanical properties. In total, 38 human cadaveric distal femur and proximal tibia bones were sectioned to produce 122 rectangular pieces of cortical bone for quantitative UTE-MT MR imaging, μCT, and biomechanical testing. Off-resonance saturation ratios (OSRs) with a series of MT pulse frequency offsets (Δf) were calculated and compared with porosity assessed with μCT, as well as elastic (modulus, yield stress, and strain) and failure (ultimate stress, failure strain, and energy) properties, using Pearson correlation and linear regression. A moderately strong negative correlation was observed between OSR and μCT porosity (R(2)  = 0.46-0.51), while a moderate positive correlation was observed between OSR and yield stress (R(2)  = 0.25-0.30) and failure stress (R(2)  = 0.31-0.35), and a weak positive correlation (R(2)  = 0.09-0.12) between OSR and Young's modulus at all off-resonance saturation frequencies. OSR determined with the UTE-MT sequence provides quantitative information on cortical bone and is sensitive to μCT porosity and biomechanical function.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of UTE ratios based on magnetization transfer and T2 for quantification of Achilles tendinopathy

Introduction: The Achilles tendon is commonly involved in mechanical, degenerative and inflammatory disease. Ultrashort echo time (UTE) imaging allows the tendon to be directly imaged, even when normal or only mildly diseased [1]. Off resonance saturation has been used for introducing contrast into UTE images; near resonance this reflects T2 whereas far from resonance magnetization transfer (MT...

متن کامل

Cortical Bone Perfusion Assessment using Inversion Recovery Ultrashort TE Imaging

Target Audience: Musculoskeletal Radiologists, Bone Metabolism Researchers Purpose: Perfusion MRI studies of vertebral trabecular bone have shown a direct relation between bone perfusion and remodeling activity. Trabecular bone studies have also shown that decreases in vascularity and perfusion may contribute to increased fracture risk in older individuals. To date, perfusion MRI of the cortica...

متن کامل

3D Ultrashort Echo Time (UTE) Imaging in the Brain at 7T

Introduction: Ultrashort echo time (UTE) imaging offers advantages in being able to directly image tissues with T2 values less than a few milliseconds, such as tendons and cortical bone [1]. In the brain, short-T2 components are present in white matter [2] believed to be associated with myelin – as well as in connective tissues and calcifications, and these are known to be altered in neurodegen...

متن کامل

Designing long-T2 suppression pulses for ultrashort echo time imaging.

Ultrashort echo time (UTE) imaging has shown promise as a technique for imaging tissues with T2 values of a few milliseconds or less. These tissues, such as tendons, menisci, and cortical bone, are normally invisible in conventional magnetic resonance imaging techniques but have signal in UTE imaging. They are difficult to visualize because they are often obscured by tissues with longer T2 valu...

متن کامل

Collagen composition and content-dependent contrast in porcine annulus fibrosus achieved by using double quantum and magnetization transfer filtered UTE MRI.

PURPOSE To test the potential of combining double quantum and magnetization transfer filtered ultra-short echo time (DQF-MT-UTE) MRI to obtain information about the macromolecular composition and characteristics of connective tissues. METHODS A DQF-MT-UTE pulse sequence was implemented on a 14.1 T AVANCE III Bruker spectrometer equipped with a Bruker micro2.5-imaging gradient system to obtain...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • NMR in biomedicine

دوره 28 7  شماره 

صفحات  -

تاریخ انتشار 2015