Infrared microspectroscopy station at BL43IR of SPring-8

نویسندگان

  • Y. Ikemoto
  • T. Moriwaki
  • T. Hirono
  • S. Kimura
  • K. Shinoda
  • M. Matsunami
  • N. Nagai
  • T. Nanba
  • K. Kobayashi
  • H. Kimura
چکیده

BL43IR of SPring-8 has been constructed for the infrared materials researches, and it covers a wide spectral range from 100 to 20,000 cm . The microspectroscopy station of this BL has a spatial resolution smaller than 10 lm in diameter in the mid-infrared region without apertures. This station had been mainly used within mid-infrared region, and its performance in the far-infrared region had not been tested. In this paper, we examined the capability of the microscope in the far-infrared region and the spatial resolution is found to be almost at the diffraction limit. The microspectroscopy station has been revealed to have a good performance for doing materials researches in all the spectral range available. 2004 Elsevier B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surface science station of the infrared beamline at SPring-8

An experimental station for surface science has been constructed at the infrared beamline (BL43IR) of SPring-8, Japan. The station utilizes synchrotron radiation in the energy range of 100–20000 cm 1 to perform infrared reflection absorption spectroscopy (IRAS) of surfaces. It consists of an experimental section, a preparation chamber, gas handling equipment and a pair of focusing optics. In si...

متن کامل

Infrared spectromicroscopy and magneto-optical imaging stations at SPring-8

At the BL43IR of SPring-8, infrared microanalysis on various kinds of solid specimens under multiple environments with a spatial resolution smaller than 10mm in diameter is planned in the infrared region. In order to perform such analysis, two different stations, a multipurpose spectromicroscopy apparatus and a magneto-optical imaging one have been constructed. Measurements on the spatial two-d...

متن کامل

Infrared beamline BL43IR at SPring-8: design and commissioning

The beamline BL43IR at SPring-8 has been constructed as a beamline exclusively dedicated to the infrared spectroscopy. The beamline was designed to make use of infrared synchrotron radiation emitted from a bending magnet of 39.3m bending radius with the acceptance angle of 36.5(H) 12.6(V)mrad and to cover a very wide wavelength range from 500 nm (20,000 cm , 2.5 eV) to 100mm (100 cm , 12.5meV)....

متن کامل

Front end and optics of infrared beamline at SPring-8

An infrared (IR) beamline, BL43IR, at SPring-8 has been constructed for IR spectroscopies under extreme conditions. The beamline covers a very wide photon energy range in the IR region and offers a brilliant IR photon beam to the experimental end stations. The IR light from SPring-8 is collected by a newly designed optical system including a so-called ‘‘magic mirror’’. The design of the optical...

متن کامل

Molecular mapping of periodontal tissues using infrared microspectroscopy

BACKGROUND: Chronic periodontitis is an inflammatory disease of the supporting structures of the teeth. Infrared microspectroscopy has the potential to simultaneously monitor multiple disease markers, including cellular infiltration and collagen catabolism, and hence differentiate diseased and healthy tissues. Therefore, our aim was to establish an infrared microspectroscopy methodology with wh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004