Application of Volumetric Modulated Arc Therapy and Simultaneous Integrated Boost Techniques to Prepare “Safe Margin” in the Rabbit VX2 Limb Tumor Model
نویسندگان
چکیده
BACKGROUND In this study, we aimed to establish the rabbit VX2 limb tumor model, and then prepare a "necrotic zone" as a safe margin by volumetric modulated arc therapy and simultaneous integrated boost (VMAT-SIB) technique applied in the areas where the tumor is located adjacent to the bone (GTVboost area). MATERIAL AND METHODS Rabbits in the control group (n=10) were not treated, while those in the test group (n=10) were treated with the SIB schedule delivering a dose of 40Gy, 35Gy, 30Gy, and 25Gy to the GTVboost, GTV (gross tumor volume), CTV (clinical target volume), and PTV (planning target volume) in 10 fractions. Magnetic resonance diffusion-weighted imaging (MRDWI), 3-dimensional power Doppler angiography (3D-PDA), and histological changes were observed after radiotherapy. RESULTS After radiotherapy, the two groups showed a significant difference in the GTVboost area. In the test group, the tumor necrosis showed a significantly low signal in DWI and high signal in apparent diffusion coefficient (ADC) maps. The 3D-PDA observation showed that tumor vascular structures decreased significantly. Histological analysis demonstrated that a necrotic zone could be generated in the GTVboost area, and microscopic examination observed cell necrosis and fibroplasia. CONCLUSIONS This studies demonstrated the feasibility of using VMAT-SIB technique in the rabbit VX2 limb tumor model. The formation of a necrotic zone can be effectively defined as safe margin in the GTVboost area. showing potential clinical applicability.
منابع مشابه
An Overview on the Clinical Application of Radiobiological Modeling in Radiation Therapy of Cancer
Submit Manuscript | http://medcraveonline.com Abbreviations: TCP: Tumor Control Probability; NTCP: Normal Tissue Control Probability; LKB: Lyman Kutcher Burman; IGRT: Image Guided Radiation Therapy; IMRT: Intensity Modulated Radiation Therapy; SIB-IMRT: Simultaneous Integrated BoostIMRT; VMAT: Volumetric Modulated Arc Therapy; DA: Double Arc; SA: Single Arc; HT: Helical Tomotherapy; IFP: Improv...
متن کاملEarly toxicity of moderate hypofractionated volumetric modulated Arc radiotherapy for localized prostate cancer
Background: Based on the radiation biology model of prostate cancer, hypofractionated radiotherapy can improve the treatment outcomes without increasing toxicity. Although hypofractionated radiotherapy is implemented over a short period of time, it is more convenient and cheaper compared with conventional fractionated treatment. The aim of this study was to investigate the early toxicity of mod...
متن کاملSimultaneous integrated boost plan comparison of volumetric‐modulated arc therapy and sliding window intensity‐modulated radiotherapy for whole pelvis irradiation of locally advanced prostate cancer
Concurrent radiotherapy to the pelvis plus a prostate boost with long-term androgen deprivation is a standard of care for locally advanced prostate cancer. IMRT has the ability to deliver highly conformal dose to the target while lowering irradiation of critical organs around the prostate. Volumetric-modulated arc therapy is able to reduce treatment time, but its impact on organ sparing is stil...
متن کاملQuantification and modelling of the dosimetric impact of the treatment couch in volumetric modulated arc therapy (VMAT)
Background: As the volumetric modulated arc therapy (VMAT) becoming a main role of treatment ways, the effect of couch top becomes more significant. It is imperative to re-evaluate the couches that previously may have been considered of no importance during early treatment techniques. The impact of couch top on radiation delivery was explored and the couch model was tested with the aim of reduc...
متن کاملDosimetric Effects of Rotational Setup Error in Volumetric Modulated Arc Radiotherapy on Brain Tumor Patients
Introduction: This study examined the dosimetric effects based on the rotational setup error to correct patient setup errors occur during volumetric modulated arc radiotherapy (VMAT) for brain tumor patients. Material and Methods: This study included 1129 cases of cone beam computed tomography (CBCT) images obtained from 46 brain tumor patients, who experienced VMAT and used the 6DoF (degree o...
متن کامل