New approach for the glaucoma detection with pupil perimetry
نویسندگان
چکیده
OBJECTIVE To calculate the pattern deviation for identifying abnormal points of pupil perimetry, and also to evaluate the grayscale display for distinguishing glaucomatous pupil field loss (abnormal test points) from normal pupil field (normal test points). METHODS Fourteen patients ranging in age from 51 to 80 years, who had normal-tension glaucoma (6 eyes) and primary open-angle glaucoma (8 eyes) were tested. Pupil perimetry (Kowa & Hamamatsu, Japan) was used to objectively measure the visual field. Also, to obtain a subjective visual field, the analysis was performed with a Humphrey Field Analyzer (30-2, Full threshold program, Carl Zeiss Meditec, Dublin). Of the 76 test points, the 22 surrounding points and the 3 points corresponding to the blind spot are excluded; and among the remaining 51 points, the 85th percentile value of pupil perimetry was calculated. The abnormal and normal test points were recorded, and the amount of positive or negative deviation of each test point from the normal median value for the corresponding test points was determined. We also used this technique to identify the value for distinguishing glaucomatous pupil field loss from the normal pupil field. RESULTS This study could be improved by calculating the sensitivity and specificity of a certain cut-off value between the normative data and the glaucoma patients. The value for identifying both abnormal and normal test points was a negative deviation of -4. Based on these results, pupil perimetry gray scales were determined: white (< -3), 25% gray (from -4 to -8), 50% gray (from -9 to -13), 75% gray (from -14 to -18) and black (> -19). Glaucomatous pupil field losses were generally distinguished from the normal pupil field by use of a gray scale. CONCLUSION Our studies demonstrated that, when a deviation of > -4 was regarded as an abnormal value, the detection of pupil perimetry exhibited improvement in glaucoma patients.
منابع مشابه
Analysis of various factors affecting pupil size in patients with glaucoma
BACKGROUND Pupil size is an important factor in predicting post-operative satisfaction. We assessed the correlation between pupil size, measured by Humphrey static perimetry, and various affecting factors in patients with glaucoma. METHODS In total, 825 eyes of 415 patients were evaluated retrospectively. Pupil size was measured with Humphrey static perimetry. Comparisons of pupil size accord...
متن کاملQuadrant Field Pupillometry Detects Melanopsin Dysfunction in Glaucoma Suspects and Early Glaucoma
It is difficult to detect visual function deficits in patients at risk for glaucoma (glaucoma suspects) and at early disease stages with conventional ophthalmic tests such as perimetry. To this end, we introduce a novel quadrant field measure of the melanopsin retinal ganglion cell mediated pupil light response corresponding with typical glaucomatous arcuate visual field defects. The melanopsin...
متن کاملThe early field defects in glaucoma.
the visual field. We cannot rule out glaucoma by testing a predetermined or specific area in the visual field. A complete examination of the visual field is best performed by using both static and kinetic perimetry together. This seems to constitute the best means of modern quantitative perimetry. Scatter of test points can be controlled only by careful attention to numerous details involving p...
متن کاملPupillary anomaly masquerading as a glaucomatous visual field defect: a case report
BACKGROUND Patients are often referred to ophthalmologists with focal visual field defects on routine testing, possibly related to a potential diagnosis of glaucoma. However, examination of the individual patient's ocular characteristics as well as facial characteristics may often reveal a cause of the visual field defect. CASE PRESENTATION We describe a patient who was found to have a superi...
متن کاملBlue Multifocal Pupillographic Objective Perimetry in Glaucoma.
PURPOSE This study investigated multifocal pupillographic objective perimetry (mfPOP) stimuli that target the intrinsic photosensitivity of melanopsin retinal ganglion cells. The diagnostic potential for glaucoma is compared between stimuli biased toward either cone input to these cells or their melanopsin response. METHODS Nineteen glaucoma patients and 24 normal subjects were tested using m...
متن کامل