Internal fixation of fractures of the proximal humerus with a humeral fixator plate (PlantTan Plate): a two year follow-up.
نویسندگان
چکیده
Fractures of the proximal humerus are common. Most can be treated conservatively with good results. However, there is no uniform treatment of displaced fractures. One option was the PlantTan Plate (PTP). We present a study of 65 patients with displaced proximal humeral fractures treated with the PTP. Patients were followed-up for 24 months assessing fracture healing, functional outcome, pain and postoperative complications. The mean patient age was 61 years (range: 17 to 86). Forty-six percent of the patients were aged over 65 years. The Constant-Murley shoulder score (CMS) to assess function and a visual analogue scale (VAS) assessing pain were used. At 24 months, the mean CMS was 76 (range: 34 to 100) for the fractured side and 85 (range: 66 to 100) for the uninjured side, the mean VAS was 22 (range: 0 to 78). We believe that this study shows that operative intervention is a viable option for displaced proximal humeral fractures.
منابع مشابه
The Outcome of Proximal Humeral Locking Plates in the Management of Three and Four Part Proximal Humeral Fractures in Special Cohort of Young Patients in High Velocity Trauma
Background: Locking plate fixation provides satisfactory outcome following proximal humerus fractures. None of theprevious studies selectively evaluate the outcome in young patients. This study evaluates outcome of locking platesystem in the treatment of acute three- and four-part fractures in young patients.Methods: In this prospective study we included all patients who were less than 60 years...
متن کاملOutcome of proximal humerus fractures treated by PHILOS plate internal fixation. Experience of a district general hospital.
Proximal humerus fractures have been a challenge to achieve stable fixation. PHILOS (Proximal Humerus internal locking system) is part of the latest generation of locking compression plates for proximal humeral fracture fixation. We aim to assess the clinical and functional outcome of proximal humeral fractures (2-part, 3-part and 4-part) treated with the PHILOS plate. We prospectively reviewed...
متن کاملA Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate
Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...
متن کاملOsteosynthesis of Proximal Humeral End Fractures with Fixed-angle Plate and Locking Screws: Technique and Results
UNLABELLED Describe the results of proximal humeral fractures surgically treated with the Philos locking plate system. METHOD Between March 2003 and October 2004 we prospectively reviewed 24 of 26 patients with proximal humerus fractures treated with a Philos plate. The mean follow-up time was 12 months and the mean age of patients was 57 years. Six patients had four-part proximal humerus fra...
متن کاملLetter to the Editor: Minimally invasive plate osteosynthesis for proximal humeral fractures.
PURPOSE To report the outcome after minimally invasive plate osteosynthesis (MIPO) through the deltoid-splitting approach for proximal humeral fractures. METHODS 10 men and 30 women aged 37 to 88 years underwent MIPO through the deltoid-splitting approach using the Proximal Humerus Internal Locking System or the Locking Proximal Humerus Plate for 2-part (n=18), 3-part (n=20), and 4-part (n=2)...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta orthopaedica Belgica
دوره 74 6 شماره
صفحات -
تاریخ انتشار 2008