Outcomes Of Distal Femur Fracture Treated With Dynamic Condylar Screw.

نویسندگان

  • Mohammad Naeem Ur Razaq
  • Taj Muhammad
  • Ashfaq Ahmed
  • Adeel
  • Sajjad Ahmad
  • Saeed Ahmad
  • Shahid Sultan
چکیده

BACKROUND Implants for open reduction and internal fixation of distal femoral fracture includes angle blade plate, rush nails, enders nail and interlocking nails. But all these devices are technically demanding and less effective in providing inter-fragmentary compression in osteoporotic bones. These problems can be solved with dynamic condylar screw (DCS).The objective of the study was to determine the frequency of different outcomes of distal femoral fracture treated with dynamic condylar screw. METHODS This case series study was carried out in the Department of Trauma & Orthopaedics, Ayub Teaching Hospital Abbottabad from 1st October 2014 to August 2015, after approval of the ethical committee of the institution. Data of all patients with distal femoral fractures aged 20-70 years, recruited through emergency, OPD or consultant clinic collected on a pro forma. Standard treatment of trauma was given to the patients. Detailed history was taken including the past medical and surgical history. Detailed examination including air-way, breathing and circulation, general physical examination and abdomino-pelvic examination was done in each patient. Investigations including urinalysis, haemoglobin %, full blood count, X-ray (both AP and lateral view) of the involved femur (including hip and knee) was done. RESULTS Mean age of the patients was 43.18±14.647 ranging from 20 to 70 years. Mean duration of hospital stay in days was 2.21±1.111 ranging from 1 to 6 days. Patients' follow-up assessment after 4 months of surgery for union of femoral fracture treated with dynamic condylar screw was found in 96 (94.1%), wound infection was found in 7 (6.9%), knee stiffness was found in 21 (20.6%) and limb shortening was found in 7 (6.9%). CONCLUSIONS Dynamic condylar screw is an easy, scientifically less difficult and satisfying method of treatment for fra.ctures of femur.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Is Distal Femur Locking Plate a Superior Implant in Distal Femur Fracture?

In spite of advances in techniques and improvements in surgical implants, confusion still prevails regarding use of specific implants in distal femur fracture. Fractures in the distal femur have posed considerable therapeutic challenges throughout the history of fracture treatment. Most of these surgical failures were due to inadequate fixation of the fracture fragments. The Aim of the study is...

متن کامل

Fractures of the distal femur treated with the AO dynamic condylar screw.

We report the results of treatment with the dynamic condylar screw of 21 cases of supracondylar and intercondylar fractures of the femur in patients aged 22 to 91 years. There were two nonunions and no deaths. We found the device easy to use and the good fixation allowed early patient mobilisation.

متن کامل

Radiologically visible surgical error and poor outcome of internal fixation in distal femoral fractures.

BACKGROUND Distal femoral fractures are usually complex and difficult to treat. The surgeon must demonstrate sound judgment in interpreting the fracture pattern and must possess a basic understanding of the principles of operative fracture management as well as knowledge of the mechanics of the implants. MATERIAL AND METHODS 1 70 patients with distal femoral fractures were operated by 10 diff...

متن کامل

Condylar buttress plate versus fixed angle condylar blade plate versus dynamic condylar screw for supracondylar intra-articular distal femoral fractures.

PURPOSE To compare outcomes of 3 fixation techniques for intra-articular distal femoral fractures. METHODS Records of 59 men and 49 women aged 16 to 80 (mean, 47) years who underwent internal fixation for 116 type-C (complete intra-articular) distal femoral fractures were retrospectively reviewed. According to the AO classification, 25 fractures were type C1 (23 closed and 2 open), 71 type C2...

متن کامل

[Distal femur fractures. Comparative analysis of two different surgical treatments].

INTRODUCTION The treatment of distal femur fractures has been a controversial topic and it has recently evolved towards indirect reduction and minimally invasive techniques. OBJECTIVE To compare the results of the surgical treatment of distal femur fractures with a plate with screws for condylar compression purposes with the minimally invasive stabilization system. MATERIAL AND METHODS Pati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of Ayub Medical College, Abbottabad : JAMC

دوره 28 2  شماره 

صفحات  -

تاریخ انتشار 2016