Improving passive filter compensation performance with active techniques
نویسندگان
چکیده
This paper presents the performance analysis of a hybrid filter composed of passive and active filters connected in series. The analysis is done by evaluating the influence of passive filter parameters variations and the effects that different active power filter’s gain have in the compensation performance of the hybrid scheme. The compensation performance is quantified by evaluating the attenuation factor in a power distribution system energizing high-power nonlinear loads compensated with passive filters and then improved with the connection of a series active power filter. Finally, compensation characteristics of the hybrid topology are tested on a 10-kVA experimental setup.
منابع مشابه
Harmonic Elimination of 25 kV AC Electric Railways Utilizing a New Hybrid Filter Structure
Thyristor rectifiers are widely used in electric railways in order to control the speed. As a consequence of their usage in addition to substantial input lead current, an enormous amount of harmonics is injected into the grid. To avoid such harmonics as well as reactive power compensation, reactive power hybrid filters consisting of active and passive filters are utilized. Regarding different p...
متن کاملMethod of Improving Voltage Quality Using Modern Power Electronics
Abstract-This paper presents a comprehensive simulation study of PI Controlled Three phase Series active power filter to improve power quality. The series active power filter employs a method for the reference compensation current based on Fast Fourier Transform Passive, L-C filters have disadvantage of fixed compensation and not fit for fast varying condition while by using auto tuned active p...
متن کاملAnn Controller Based Adaptive Shunt Hybrid Filter for Static and Dynamic Loads
Chapter 3 presents ANN based adaptive shunt passive filter, whose performance is found to be superior to fixed element shunt passive filter in harmonic and reactive compensation. However, the drawback is that it can provide only partial harmonic and reactive power compensation. Hence, an ANN based digital controller for active filter is developed. It compensates for the major portion of source ...
متن کاملMitigation of Switching Harmonics in Shunt Active Power Filter Based on Variable Structure Control Approach
This paper presents a novel control approach used in shunt active power filter based on variable structure control combined with Random PWM technique (RVSC) that provides robust, fast, and more favorable performance for active power filter. This control strategy is compared with two other strategies to show the effectiveness of the introduced methods; pulse width modulated proportional-integral...
متن کاملAdvanced configuration of hybrid passive filter for reactive power and harmonic compensation
Harmonics is one of the major power quality problems for power systems. The harmonics can be eliminated by power filters such as passive, active, and hybrid. In this study, a new passive filter configuration has been improved in addition to the existing passive filter configurations. Conventional hybrid passive filters are not successful to compensate rapidly changing reactive power demand. The...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- IEEE Trans. Industrial Electronics
دوره 50 شماره
صفحات -
تاریخ انتشار 2003