An assessment of the performance of the Chemispek J200 in a hospital laboratory
نویسندگان
چکیده
(1) The sampler is electronically variable for both wash and sample time. The 60-position sample plate is removable. (2) Each pump and gear-box serves a pair of analytical platforms. Each pump has four speeds. There is one operating speed (5 rev./min.), one fast and two slow speeds. (3) The reagent valves have three positions, reagent, wash and a clamped position to prevent reagents running back. Each analytical platform is controlled by its own set of reagent valves. (4) There is an analytical platform for each chemistry, except sodium and potassium. The platform contains a special block to facilitate the introduction ofair bubbles into the liquid phase in a uniform manner. Mixing coils, dialysers, heating bath and connecting tubing are all located on the platform. The waste from the flow cell drains away under the platform where it is piped into a central drain. (5) The twin-channel photometer incorporates a quartz iodine light-source and an interference filter for each channel. Each channel has its own circuitry to allow for normal or inverse chemistry, blank correction mode and curve regeneration. The photometer uses a special 5mm flow cell which has angled reflective glass surfaces at each end. This enables the photometer to use an energy gating system to measure the optical density of the liquid phase without the need to debubble. (6) A flame photometer with integral diluter (Corning 455) is connected to the microprocessor via a digital analogue converter. The sample is obtained using a split-stream connector connected to the sample line. (7) A Bryans Southern six-pen recorder is used to monitor the six channels (1/6 full-scale deflection or full-scale deflection). Each channel can be controlled independently for scale deflection. (8) A 16-channel microprocessor is used to monitor the signals from all photometers. Each chemistry is assigned its own microprocessor channel which standardizes, calculates and corrects for carry-over and drift. The results for each channel are then printed out
منابع مشابه
Performance of Tunisian Public Hospitals: A Comparative Assessment Using the Pabón Lasso Model
Background and Objectives: Constant monitoring of healthcare organizations’ performance is an integral part of informed health policy-making. Several hospital performance assessment methods have been proposed in the literature. Pabon Lasso Model offers a fast and convenient method for comparative evaluation of hospital performance. This study aimed to evaluate the relative performance of hospit...
متن کاملCapillarys 3 Octa®: Analytical Performance Assessment for HbA1c Quantification
Objective: Determination of HbA1c level is a precious indicator for therapeutic follow-up of patients with type 1 or type 2 diabetes. Our study aimed to evaluate the analytical characteristics of Capillarys 3 Octa® HbA1c measurement by capillary electrophoresis. Materials and Methods: Our study involved 265 venous whole blood specimens repeatability, intermediate fidelity, accuracy, linearity,...
متن کاملAssessment and Comparing of Hospital Performance Using “Accreditation Pattern”, “Organizational Excellence Pattern” and Program Chain Patterns
Introduction: Hospital performance measurement is an essential part for providing feedback on the efficacy and effectiveness of services. The purpose of this study was assessment and comparing of hospital performance using “Accreditation Pattern”, “Organizational Excellence Pattern “and Program Chain (IPOCC) Patterns. Methods: This descriptive-comparative study was conducted in 2019 in the ed...
متن کاملDevelopment of an Assessment Model for Evaluating the Performance of Nursing Services
A Model for Evaluating the Performance of Nursing Services
متن کاملQuantitative Assessment of Analytical Phase Quality of Clinical Biochemistry Parameters Using Sigma Metrics
Background and Aims: Six sigma is the latest version of total quality management. It is quantitative goal for process performance. With increasing demands for improved accuracy and reliability of the results, Six Sigma is gaining increased visibility in the clinical laboratory process outcomes. The aim of study was to evaluate the quality of analytical phase performance in a clinical biochemist...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of Automatic Chemistry
دوره 4 شماره
صفحات -
تاریخ انتشار 1982