An in vitro biomechanical evaluation of an expansive double-threaded bi-directional compression screw for fixation of type II odontoid process fractures
نویسندگان
چکیده
Odontoid process fracture accounts for 5% to 15% of all cervical spine injuries, and the rate is higher among elderly people. The anterior cannulated screw fixation has been widely used in odontoid process fracture, but the fixation strength may still be limited under some circumstances. This study aims to investigate the biomechanical fixation strength of expansive double-threaded bi-directional compression screw (EDBCS) compared with cannulated lag screw (CLS) and improved Herbert screw (IHS) for fixation of type II odontoid process fracture.Thirty fresh cadaveric C2 vertebrae specimens were harvested and randomly divided into groups A, B, and C. A type II fracture model was simulated by osteotomy. Then the specimens of the 3 groups were stabilized with a single CLS, IHS, or EDBCS, respectively. Each specimen was tested in torsion from 0° to 1.25° for 75 s in each of 5 cycles clockwise and 5 cycles anticlockwise. Shear and tensile forces were applied at the anterior-to-posterior and proximal-to-distal directions, respectively, both to a maximum load of 45 N and at a speed of 1 mm/min.The mean torsional stiffness was 0.309 N m/deg for IHS and 0.389 N m/deg for EDBCS, which were significantly greater compared with CLS, respectively (0.169 N m/deg) (P < .05 and P < .05). The mean shear stiffness for the EDBCS was 238 N/mm, which was significantly greater than CLS (150 N/mm) and IHS (132 N/mm) (P < .05 and P < .05). All 3 screws only partly restored tensile stiffness, but not significantly.Fixation with the EDBCS can improve the biomechanical strength for odontoid process fracture compared with CLS and IHS, especially in terms of torsional and shear stiffness.
منابع مشابه
Odontoid screw fixation for fresh and remote fractures.
Fractures of the odontoid process are common, accounting for 10% to 20% of all cervical spine fractures. Odontoid process fractures are classified into three types depending on the location of the fracture line. Various treatment options are available for each of these fracture types and include application of a cervical orthosis, direct anterior screw fixation, and posterior cervical fusion. I...
متن کاملBiomechanical evaluation of four different posterior screw and rod fixation techniques for the treatment of the odontoid fractures.
Problems that screw cannot be inserted may occur in screw-rod fixation techniques such as Harms technique. We compared the biomechanical stability imparted to the C-2 vertebrae by four designed posterior screw and rod fixation techniques for the management of odontoid fractures. A three-dimensional finite element model of the odontoid fracture was established by subtracting several unit structu...
متن کاملComplication Avoidance and Management Using the O-arm for Odontoid Screw Fixation: Technical Note
Objective: Odontoid screw fixation is an accepted surgical approach for Type 2 odontoid fractures with an intact transverse ligament. Typically, intraoperative bi-planar flouroscopy is used for placement of an odontoid screw. However, the quality of the images obtained with bi-planar fluoroscopy in the operating room is variable (due to patient body habitus) and screws may be misplaced. We repo...
متن کاملManagement of Type II Odontoid Fracture for Osteoporotic Bone Structure: Preliminary Report.
AIM Anterior transodontoid screw fixation technique is generally chosen for the management of type II odontoid fractures. The nonunion of type II odontoid fractures is still a major problem especially in elderly and osteoporotic patients. Eleven osteoporotic type II odontoid fracured patients were presented in this article. MATERIAL AND METHODS We have divided 11 patients in two groups as cla...
متن کاملAn intramedullary Echidna pin for fixation of comminuted clavicle fractures: a biomechanical study
BACKGROUND Intramedullary fixation of comminuted mid-shaft clavicle fractures has traditionally been employed with satisfactory clinical outcomes; however, pins with smooth surfaces may protrude from the bone and are prone to migration, while some threaded pins are difficult to remove post-operatively. The aim of this proof-of-concept study was to develop and evaluate the biomechanical strength...
متن کامل