Evaluation and comparison of dissolution data derived from different modified release dosage forms: an alternative method.
نویسندگان
چکیده
Dissolution testing is an essential requirement for the development, establishment of in vitro dissolution and in vivo performance (IVIVR), registration and quality control of solid oral dosage forms. The objective of the present study was to investigate the effect of delivery system positioning in accordance with the USP 23-recommended dissolution methods and the proposed modification on drug release from controlled release systems having different operating release mechanisms, namely, swellable floatable, swellable sticking and osmotic pump. The delivery systems were evaluated by placing each dosage form either in the dissolution vessel in accordance with the USP 23 methods or over/below a designed ring/mesh device for achieving full surface exposure to the dissolution medium for sticking or floatable systems respectively. Results indicate that the overall release profiles from the sticking and floatable systems of theophylline are sensitive to their positioning in the dissolution vessel (P<0.05). Furthermore, release of diltiazem hydrochloride from the sticking system also demonstrated sensitivity (P<0.05). In contrast, the floatable dosage form of this latter drug with the application of a helical wire sinker, or when it was placed below the ring/mesh assembly, or by allowing the dosage form to float, did not show sensitivity (P>0.05) for the overall release behavior. This was attributed to the greater solubility of diltiazem hydrochloride (50% solubility in water at 25 degreesC) in comparison to theophylline which is a sparingly soluble drug (0.85% solubility in water at 25 degreesC). Drug release from the osmotic pump appeared to be identical under the given experimental conditions (P>0.05). Statistical analysis of data was performed by comparing the t50%, t70%, t90%; mean dissolution times (MDT50%, MDT70%, MDT90%); the "difference factor, f1" and "similarity factor, f2". It is concluded that the results derived from the application of the "similarity factor, f2" are superior to the individual time points (e.g. tx%) and MDTx% values in differentiating between overall release patterns or the border line release profile differences. It also became apparent that in the case of the swellable sticking systems full surface exposure to the dissolution medium results in greater release rate. For the osmotic pump the required osmotic pressure threshold necessary for constant rate drug delivery appears to have reached independent of the hydrodynamic conditions. A successful and more accurate evaluation of dissolution data can be derived when full surface exposure is considered and this can be accomplished by dissolution method modification with the aid of the designed ring/mesh assembly.
منابع مشابه
Comparative Assessment of Different Dissolution Apparatus for Floating Drug Delivery Systems
INTRODUCTION Dissolution testing is an in vitro technique of great importance in formulation and development of pharmaceutical dosage forms,as it can be used as a substitute for in vivo studies under strictly defined and specified conditions (1). For the comparison of in vitro dissolution data and for use of such data for in vivo bioequivalence testing and in vitro-in vivo correlations (IVIVC) ...
متن کاملEvaluation of Okra gum as a binder in tablet dosage forms
The type and the amount of binders decisively influence the characteristics of tablets prepared by wet granulation procedure. Commonly used binders like acacia, gelatin, starch and hydrolyzed starch have natural origin. The aim of this study was to evaluate the effectiveness of a new binder extracted from Hibiscus esculentus (Okra gum) in tableting. binder Hibiscus esculentus gum was extracted ...
متن کاملDesign, Evaluation and Comparative Study of Pulsatile Release from Tablet and Capsule Dosage Forms
The objective of present research was to design, evaluate and compare drug release from two different dosage forms in pulsatile drug delivery system (DDS) for Metoprolol tartarate (MT) as tablet and capsule. Pulsatile systems are gaining a lot of interest as they deliver the drug at the right site of action at the right time and in the right amount, thus providing spatial and temporal del...
متن کاملEvaluation of Okra gum as a binder in tablet dosage forms
The type and the amount of binders decisively influence the characteristics of tablets prepared by wet granulation procedure. Commonly used binders like acacia, gelatin, starch and hydrolyzed starch have natural origin. The aim of this study was to evaluate the effectiveness of a new binder extracted from Hibiscus esculentus (Okra gum) in tableting. binder Hibiscus esculentus gum was extracted ...
متن کاملDesign and Comparative Evaluation of In-vitro Drug Release, Pharmacokinetics and Gamma Scintigraphic Analysis of Controlled Release Tablets Using Novel pH Sensitive Starch and Modified Starchacrylate Graft Copolymer Matrices
The present investigation deals with the development of controlled release tablets of salbutamol sulphate using graft copolymers (St-g-PMMA and Ast-g-PMMA) of starch and acetylated starch. Drug excipient compatibility was spectroscopically analyzed via FT-IR, which confirmed no interaction between drug and other excipients. Formulations were evaluated for physical characteristics like hardness,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of controlled release : official journal of the Controlled Release Society
دوره 55 1 شماره
صفحات -
تاریخ انتشار 1998