PURPOSES To examine radiographically the component motion in a bipolar prosthesis and to determine whether the self-centering mechanism really works in vivo. METHODS 38 patients with 41 bipolar hip endoprostheses (30 for coxarthrosis and 11 for osteonecrosis of femoral head) were included in this study. Two radiographs of each case were taken to evaluate the self-centering mechanism. The first anteroposterior radiograph of both hip joints was taken at the maximum abduction while the patient standing on the endoprosthetic leg. The second radiograph was taken after the patient returned to neutral position while standing on 2 legs. In the present study, the order in which the radiographs were taken differed from previously reported studies. The radiographs were analysed using the method similar to that of Drinker and Murray. The adductive motion from abduction to a neutral position is within the range of inner bearing oscillation. RESULTS The outer head alignment changed from 23 degrees to 12 degrees in the patients with osteonecrosis. However, the valgus position of the outer head (36 degrees) remained unchanged in the patients with coxarthrosis standing on 2 legs in the neutral position. CONCLUSION The self-centering mechanism of the bipolar endoprosthesis functioned in the patients with osteonecrosis, but did not work in the coxarthrosis group.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Unipolar, Bipolar or Total Hip Endoprosthesis after Femoral Neck Fracture: What is a Right Decision?

Received: 27. 02. 2006. Accepted: 08. 06. 2006. The aim of this study �as to recognize differences in midterm clinical outcome after femoral neck fracture and hip endoprosthesis implantation. A total of 145 patients �ere examined, 32 patients �ith unipolar, 70 �ith bipolar and 43 patients �ith total hip endoprosthesis. The mean values of Harris Hip Score, after 3.8 ± 1.9 years, �ere: 72.1 ± 17....

متن کامل

Different Types of Hip Endoprostheses after Osteoporotic Femoral Neck Fracture; Functional Results?

Aim of this study was to recognize differences in long-term clinical outcome after femoral neck fracture and hip endoprosthesis implantation. Total of 145 patients were examined, 32 patients with unipolar, 70 with bipolar and 43 patients with total hip endoprosthesis. The mean values of Harris hip score, after 3.8 ± 1.9 years, were: 72.1 ± 17.8, 74.27 ± 19.1, 78.2 ± 22.5 for patients with unipo...

متن کامل

Biomechanical and clinical alterations of the hip joint following femoral neck fracture and implantation of bipolar hip endoprosthesis.

The implantation of a bipolar partial hip endoprosthesis is a treatment of choice for displaced medial femoral neck fracture. We present an experimental study which asses and compare biomechanical and clinical status through period before and after hip fracture and implantation of bipolar partial hip endoprosthesis. This study encompassed 75 patients who suffered from an acute medial femoral ne...

متن کامل

A dislocation of the inner head in bipolar prosthesis with a self-centering system: a case report.

We present a case of inner head dislocation 11 years after the replacement of a bipolar prosthesis with a self-centering system. An 84-year-old woman with osteoarthritis of the left hip underwent a replacement of the Bateman UPF-II bipolar prosthesis in 1987. She fell off a chair on April 19 1998, and felt a sudden sharp pain in the left hip. Roentgenograms revealed that the inner head was disl...

متن کامل

Treatment of Femoral Neck Fractures: Unipolar Versus Bipolar Hemiarthroplasty

BACKGROUND AND OBJECTIVE Intracapsular femoral neck fractures are common in the elderly population. To avoid the poor outcome of internal fixation and for early mobilization, hemiarthroplasty is performed. However, there is inadequate evidence to support the choice between unipolar or bipolar hemiarthroplasty. The aim of this study was to compare the outcome of unipolar with the bipolar prosthe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic surgery

دوره 13 1  شماره 

صفحات  -

تاریخ انتشار 2005