Corrective measures for compromised oxygen delivery during endotracheal tube cuff deflation with high-frequency percussive ventilation.

نویسندگان

  • Patrick F Allan
  • Gregory Naworol
چکیده

OBJECTIVE To determine the effect of endotracheal-tube cuff deflation on airflow and F(IO2) during high-frequency percussive ventilation (HFPV), and explore methods of correcting the cuff-deflation-associated decrease in mean airway pressure and F(IO2) at the carina. METHODS Using a mechanical lung model in our respiratory research laboratory, we measured circuit pressure near the connection to the endotracheal tube (P(vent)), mean airway pressure (P(aw)), pulsatile tidal volume (V(T)), and F(IO2) at the artificial carina. During cuff deflation we manipulated the pulsatile frequency, pulsatile flow, and the HFPV integral nebulizer. We then assessed 4 methods of correcting the decreased F(IO2) and airway pressure during cuff deflation: (1) oxygen delivery at the inspiratory fail-safe valve, (2) oxygen delivery at the T-piece between the HFPV and the endotracheal tube, (3) continuous activation of the HFPV's integral nebulizer, and (4) oxygen insufflation into the suction channel of the endotracheal tube. RESULTS Cuff deflation reduced P(vent), P(aw), pulsatile V(T), and F(IO2). Increasing the pulsatile flow and decreasing the pulsatile frequency further reduced F(IO2) during cuff deflation. Injecting supplemental oxygen at the inspiratory fail-safe valve provided the best F(IO2) increase. Injecting oxygen at the T-piece provided the second best F(IO2) increase. Continuous activation of the integral nebulizer provided the third best F(IO2) increase. Oxygen insufflation to the suction channel was least effective in correcting the F(IO2) decrease caused by cuff deflation. CONCLUSION Cuff-deflation-associated F(IO2), P(aw), and pulsatile V(T) compromise can be partially corrected by any of the 4 methods we studied. Injecting supplemental oxygen at the inspiratory fail-safe valve is the most effective method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of pulsatile tidal volume, pressure amplitude, and gas flow during high-frequency percussive ventilation, with and without partial cuff deflation.

OBJECTIVE With a high-frequency percussive ventilator and a mechanical lung model, to measure tidal volume (V(T)), pulsatile pressure amplitude (difference between peak and nadir pulsatile pressure [DeltaP];), and mean airway pressure (P (aw)) at various pulsatile frequencies, pulsatile inspiratory-expiratory ratios (I:E(p)), and pressures (measured at the interface between the pulse-generator ...

متن کامل

بررسی تاثیر تغییر وضعیت بدن بر فشار کاف لوله تراشه در بیماران تحت تهویه مکانیکی

Background: Endotracheal tube cuff pressure must be maintained in safe range. Many factors could be affecting on endotracheal tube cuff pressure in patients on mechanical ventilation. Patients undergoing mechanical ventilation (MV) in critical care settings require changing position for different reasons. The aim of this study was to determine the effect of changes in body position and head of ...

متن کامل

Use of ETView Tracheoscopic Ventilation Tube® in airway management of a patient with tracheal injury.

I tracheobronchial injuries are fatal complications requiring immediate diagnosis and treatment. Unintentional one sided intubation, endotracheal tube cuff over-inflation, direct trauma with guides or boogie’s, double-lumen tube employment, tube replacement without cuff deflation and coughing against closed or blocked ventilation circuits are the possible causes.1, 2 Emergency or difficult intu...

متن کامل

Study of endotracheal tube cuff pressure and time of measurement among intensive care units patients

Introduction: The pressure in the endotracheal tube cuff must be kept within an optimal range, to make sure tracheal capillaries circulation still stable during positive ventilation. This is essential to avoid oral and gastric stuffing aspiration Objective: The objective of this study was to assess the endotracheal tube cuff pressure and time intervals measurements among intensive care units...

متن کامل

Effect of applying positive pressure with or without endotracheal suctioning during extubation: a laboratory study.

BACKGROUND During invasive mechanical ventilation, secretions accumulate in the subglottic space; consequently, there is a risk of aspiration of these secretions into the airway during cuff deflation and extubation. To minimize this risk, 2 extubation methods are used. The first consists of introducing a suction catheter into the endotracheal tube (ETT) and the trachea. After initiating suction...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 52 3  شماره 

صفحات  -

تاریخ انتشار 2007