Evaluationof Curing Depth of Bulk-Fill Resin Composite (A comparative study)

نویسندگان

  • Salam A. Al-Araji
  • Mohammed A. Ibrahim
  • Hala A. Ragab
چکیده

Received 4 November 2014 Accepted 1 December 2014 Abstract This study evaluated the depth of cure (DOC) of recently introduced resin composites for posterior use, bulk filled flowable composite (SureFil® SDR® flow DENTSPLY Caulk) at different depth. 30 specimens were prepared and divided into two Groups,Group 1: specimens with 2 mm depth, Group 2: specimens with 4mm depth. The composite specimens were prepared by using molds of different depth, one of them with was a hole of 4 mm depth and 4 mm internal diameter and the other was with a depth of 2 mm at the same diameter. The hole was bulk filled with SDR flowable composite resin and light cured for 20 seconds with a modern high-intensity LED curing unit (EliparTM S10, 3M.US.), followed by 24 hours storage in complete darkness incubator at 37 C. The degree of conversion was measured on the top and the bottom for both depths using Fourier transform infrared (FTIR) spectroscopy. A bulk filled flowable (SDR)revealed a significant difference in degree of conversion (DOC) when the bottom surface of the specimen witha 2mm depth (DOC=76.27112163) wascompared with the bottom surface of the 4mm depth specimen (DOC=73.92160935). The 2mm depth wasshown statistically significantly higher mean values degree of conversion than 4 mm depth (P-value = 0.032). There was no statistically significant difference in the degree of conversion mean values between the top and the bottom surfaces of the specimen of the same group (P >0.05). Upon the result of thisin vitro study, it was found that the degree of conversion of the SDR bulk-fill flowable resin compositewasaffected by depths. As the depth of the resin compositewas increased the degree of conversion was decreased.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Curing Time on Polymerization Rate of Bulk-Fill Composite Resins

Objectives: The aim of this study was to compare polymerization depth of two bulk-fill and one conventional composite cured for different times. Methods: This in vitro experimental study was conducted on 54 composite samples (2×4×10mm) fabricated of Tetric N-Ceram bulk-fill, x-tra fil bulk-fill, and Grandio conventional composite cured for 20, 30, and 40 seconds. The microhardnes...

متن کامل

A Comparative Study of Shear Bond Strength of Bulk-Fill Composites, Packable and Flowable, as Well as Conventional Light-Curing Composite

Introduction: This study aimed to compare the Shear Bond Strength (SBS) of two bulk-fill composites versus a conventional resin composite. Materials and Methods: In this study, 60 sound extracted human premolars were selected and sectioned horizontally from one-third of the coronal crown to expose dentin using a low-speed cutting saw. The dentin bonding agent was applied to all specimens, then...

متن کامل

Relative Microhardness and Flexural Strength of Different Bulk Fill Resin Composite Restorative Materials

Aim: to find out if there is a significant difference in the curing efficiency at the claimed 4 mm depth and in the mechanical properties between the tested pasteform bulk fill resin composite materials. Materials and Methods: Three paste-consistency bulk-fill resin composites were used in this study (Filtek bulk fill3M; X-trafilVoco; and SonicFill bulk-fillKerr). For the microhardness testing,...

متن کامل

Wear Resistance of Bulk-fill Composite Resin Restorative Materials Polymerized under different Curing Intensities.

INTRODUCTION The aim of this study was to assess the wear resistance of four bulk-fill composite resin restorative materials cured using high- and low-intensity lights. MATERIALS AND METHODS Twenty-four samples were prepared from each composite resin material (Tetric N-Ceram, SonicFill, Smart Dentin Replacement, Filtek Bulk-Fill) resulting in a total of 96 samples; they were placed into a mol...

متن کامل

Factors affecting marginal integrity of class II bulk-fill composite resin restorations

Background. Bulk-fill composite resins are a new type of resin-based composite resins, claimed to have the capacity to be placed in thick layers, up to 4 mm. This study was carried out to evaluate factors affecting gap formation in Cl II cavities restored using the bulk-fill technique. Methods. A total of 60 third molars were used in this study. Two Cl II cavities were prepared in each tooth, o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015