Using acetabular fossa as a guide for anticipated inclination of uncemented cup in total hip replacement.

نویسندگان

  • Junwei Li
  • Xu Gao
  • Guanghui Yang
  • Yanru Zhang
چکیده

Positions of acetabular implant generally are considered to be major causative factors of dislocation. Accurate and consistent achievement of the preoperatively anticipated orientation of the acetabular cup is a great challenge in total hip replacement (THR). In the present study, we investigated the surgical application of acetabular fossa as a guide for anticipated inclination of uncemented cup, and evaluated its accuracy as an anatomic reference for achieving the preoperatively anticipated abduction of the acetabular cup in comparison with traditional device method on cadaveric specimens. Sixteen normal adult pelvic cadaveric specimens were collected. On each of the sixteen normal adult pelvic cadaveric specimens, acetabular fossa related anatomic sites were marked and studied on pelvic radiographs. Our results showed that there is close correlation between most medial aspect of acetabular sourcil and central axis of the acetabular cup at anticipated inclination of 40° ± 5°. And the fossa group can achieve the preoperatively anticipated cup abduction more accurately than the device group. The current results demonstrated that acetabular fossa can be a reasonable alternative, or as a complement to the currently used methods guiding total hip replacement.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Medium-term outcome of total hip replacement for dysplastic hips in Singapore.

PURPOSE To review medium-term outcomes of 46 patients who underwent total hip replacement (THR) for osteoarthritis secondary to dysplastic hips. METHODS Records of 58 hips in 6 men and 40 women aged 32 to 76 (mean, 62) years who underwent THR for osteoarthritis secondary to dysplastic hips and had been followed up for a mean of 4 (range, 2-8) years were retrospectively reviewed. The hips were...

متن کامل

Comparison of acetabular reamings during hip resurfacing versus uncemented total hip arthroplasty.

PURPOSE To compare the quantity of bone removed from the acetabulum during resurfacing hip arthroplasty versus uncemented total hip arthroplasty (THA). METHODS 62 consecutive patients with osteoarthritis of the hip were prospectively studied. 24 men and 7 women aged 40 to 86 (mean, 59) years underwent Birmingham hip resurfacing. 13 men and 18 women aged 34 to 88 (mean, 61) years underwent unc...

متن کامل

Accuracy of acetabular cup positioning using imageless navigation

BACKGROUND Correct placement of the acetabular cup is a crucial step in total hip replacement to achieve a satisfactory result and remains a challenge with free-hand techniques. Imageless navigation may provide a viable alternative to free-hand technique and improve placement significantly. The purpose of this project was to assess and validate intra-operative placement values for both inclinat...

متن کامل

Is the transverse acetabular ligament a reliable cup orientation guide?

BACKGROUND AND PURPOSE It is controversial whether the transverse acetabular ligament (TAL) is a reliable guide for determining the cup orientation during total hip arthroplasty (THA). We investigated the variations in TAL anatomy and the TAL-guided cup orientation. METHODS 80 hips with osteoarthritis secondary to hip dysplasia (OA) and 80 hips with osteonecrosis of the femoral head (ON) were...

متن کامل

A cemented cup with acetabular impaction bone grafting is more cost-effective than an uncemented cup in patients under 50 years.

PURPOSE Acetabular deficiencies in young patients can be restored in several ways during total hip arthroplasty. Currently, cementless cups are most frequently used. Impaction bone grafting of acetabular defects is a more biological approach, but is it cost-effective in young patients on the long term? METHODS We designed a decision model for a cost-utility analysis of a cemented cup with ace...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • International journal of clinical and experimental medicine

دوره 8 1  شماره 

صفحات  -

تاریخ انتشار 2015