Wearable cardioverter defibrillator: Bridge or alternative to implantation?
نویسندگان
چکیده
The implantable cardioverter-defibrillator (ICD) is effective to prevent sudden cardiac death (SCD) in selected patients with heart disease known to be at high risk for ventricular arrhythmia. Nevertheless, this invasive and definitive therapy is not indicated in patients with potentially transient or reversible causes of sudden death, or in patients with temporary contra-indication for ICD placement. The wearable cardioverter defibrillator (WCD) is increasingly used for SCD prevention both in patients awaiting ICD implantation or with an estimated high risk of ventricular arrhythmia though to be transient. We conducted a review of current clinical uses and benefits of the WCD, and described its technical aspects, limitations and perspectives.
منابع مشابه
Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus
Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...
متن کاملFirst experience with the wearable cardioverter defibrillator in the Netherlands
The implantable cardioverter defibrillator (ICD) has significantly improved survival in patients with an increased risk of sudden cardiac death (SCD). The wearable cardioverter defibrillator (WCD) is an alternative to the ICD in patients with a transient ICD indication or those in whom an ICD temporarily cannot be implanted. We describe here the technical details of the WCD and report three pat...
متن کاملThe Role of the Wearable Cardioverter- Defibrillator In Contemporary Clinical Practice
The implantable cardioverter-defibrillator (ICD) has been shown to improve survival in patients at high risk for sudden cardiac arrest (SCA). However, there remain situations in which an ICD may be inappropriate: the high risk for SCA is temporary, there is need for interruption of implanted ICD therapy (e.g. for infection), there is temporary inability to implant an ICD, there is bridge period...
متن کاملNew horizon for infection prevention technology and implantable device
There has been a significant increase in the number of patients receiving cardiovascular implantable electronic devices (CIED) over the last two decades. CIED infection represents a serious complication after CIED implantation and is associated with significant morbidity and mortality. Recently, newly advanced technologies have offered attractive and suitable therapeutic alternatives. Notably, ...
متن کاملValue of The Wearable Cardioverter Defibrillator (WCD) as a Bridging-Therapy before Implantation of a Cardioverter Defibrillator (ICD).
Wearable cardioverter defibrillators (WCD), initially available in 2002, have recently experienced more routine use in many institutions as a means of preventing sudden cardiac death (SCD) prior to implantable cardioverter defibrillator (ICD) evaluation or implantation. WCD differ from ICD by their noninvasive nature, making them well suited for patient populations who have a chance for signifi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 9 شماره
صفحات -
تاریخ انتشار 2017