Blood and urine metal ion levels in young and active patients after Birmingham hip resurfacing arthroplasty: four-year results of a prospective longitudinal study.

نویسندگان

  • J Daniel
  • H Ziaee
  • C Pradhan
  • P B Pynsent
  • D J W McMinn
چکیده

This is a longitudinal study of the daily urinary output and the concentrations in whole blood of cobalt and chromium in patients with metal-on-metal resurfacings over a period of four years. Twelve-hour urine collections and whole blood specimens were collected before and periodically after a Birmingham hip resurfacing in 26 patients. All ion analyses were carried out using a high-resolution inductively-coupled plasma mass spectrometer. Clinical and radiological assessment, hip function scoring and activity level assessment revealed excellent hip function. There was a significant early increase in urinary metal output, reaching a peak at six months for cobalt and one year for chromium post-operatively. There was thereafter a steady decrease in the median urinary output of cobalt over the following three years, although the differences are not statistically significant. The mean whole blood levels of cobalt and chromium also showed a significant increase between the pre-operative and one-year post-operative periods. The blood levels then decreased to a lower level at four years, compared with the one-year levels. This late reduction was statistically significant for chromium but not for cobalt. The effects of systemic metal ion exposure in patients with metal-on-metal resurfacing arthroplasties continue to be a matter of concern. The levels in this study provide a baseline against which the in vivo wear performance of newer bearings can be compared.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Metal ion levels in large-diameter total hip and resurfacing hip arthroplasty-Preliminary results of a prospective five year study after two years of follow-up

BACKGROUND Metal-on-metal hip resurfacing is an alternative to metal-on-metal total hip arthroplasty, especially for young and physically active patients. However, wear which might be detected by increased serum ion levels is a matter of concern. METHODS The aims of this preliminary study were to determine the raise of metal ion levels at 2-years follow-up in a prospective setting and to eval...

متن کامل

How Do Metal Ion Levels Change over Time in Hip Resurfacing Patients? A Cohort Study

Metal-on-metal hip resurfacing (MOM-HR) is offered as an alternative to traditional hip arthroplasty for young, active adults with advanced osteoarthritis. Nevertheless, concerns remain regarding wear and corrosion of the bearing surfaces and the resulting increase in metal ion levels. We evaluated three cohorts of patients with Birmingham hip resurfacing (BHR) at an average follow-up of 2, 5, ...

متن کامل

Six-year results of a prospective study of metal ion levels in young patients with metal-on-metal hip resurfacings.

We describe the findings at six years in an ongoing prospective clinicoradiological and metal ion study in a cohort of 26 consecutive male patients with unilateral Birmingham Hip Resurfacing arthroplasties with one of two femoral head sizes (50 mm and 54 mm). Their mean age was 52.9 years (29 to 67). We have previously shown an early increase in the 24-hour urinary excretion of metal ions, reac...

متن کامل

Hip resurfacing versus metal-on-metal total hip arthroplasty - are metal ion levels different?

A systematic review and meta-analysis of trials comparing hip resurfacing to metal-on-metal total hip arthroplasty was conducted to determine if there is a difference in serum metal ion levels in patients receiving these implants. EMBASE and MEDLINE databases were searched from inception to December 2010 for all trials involving the use of these devices. Eligibility for inclusion in the review ...

متن کامل

Blood and urine metal ion levels in young and active patients after Birmingham hip resurfacing arthroplasty.

We welcome letters to the Editor concerning articles which have recently been published. Such letters will be subject to the usual stages of selection and editing; where appropriate, the authors of the original article will be offered the opportunity to reply. Letters should normally be under 300 words in length, doublespaced throughout, signed by all authors and fully referenced. The edited ve...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 89 2  شماره 

صفحات  -

تاریخ انتشار 2007