Lysis of the orbicularis retaining ligament and orbicularis oculi insertion: a powerful modality for lower eyelid and cheek rejuvenation.

نویسنده

  • Jeffrey D Schiller
چکیده

BACKGROUND The techniques of lower blepharoplasty are evolving to reflect the concept that the lower eyelid contour does not stop at the inferior orbital rim, and that the lid-cheek junction must often be modified to restore the midface to a youthful configuration. Multiple procedures have been proposed to smooth the lid-cheek junction and tear trough. The author proposes a technique of carbon dioxide laser lysis of the orbicularis retaining ligament and of the orbicularis oculi insertion onto the maxilla to release the tethering of the lower lid and cheek and allow recontouring of the lid-cheek junction in an extended transcutaneous lower blepharoplasty. METHODS Retrospective review of 80 extended lower blepharoplasty procedures with carbon dioxide laser lysis of the orbicularis retaining ligament and of the orbicularis oculi insertion performed in the past 3 years was undertaken. Follow-up ranged from 4 to 26 months, with an average of 7.2 months. The efficacy, risks, and complications of this procedure were assessed. RESULTS The complication rate for this procedure is not significantly higher than that for standard transcutaneous blepharoplasty, and the procedure allows significant improvement of the lid-cheek junction and rejuvenation of the upper midface. CONCLUSIONS Lysis of the orbicularis retaining ligament and lower orbicularis oculi insertion is a safe and effective adjunct to lower blepharoplasty. It is a powerful modality that allows significant rejuvenation of the lid-cheek complex and upper cheek. CLINICAL QUESTION/LEVEL OF EVIDENCE Therapeutic, IV.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Midcheek Lift Using Facial Soft-Tissue Spaces of the Midcheek.

BACKGROUND This article describes a preperiosteal midcheek lift technique performed by means of the midcheek soft-tissue spaces by precise release of the retaining ligaments that separate the spaces. METHODS From November of 2009 to June of 2014, 184 patients underwent this procedure. A transcutaneous lower eyelid blepharoplasty incision was used to access the preseptal space. Medially, the o...

متن کامل

The five-step lower blepharoplasty: blending the eyelid-cheek junction.

BACKGROUND Lower lid blepharoplasty has potential for significant long-lasting complications and marginal aesthetic outcomes if not performed correctly, or if one disregards the anatomical aspects of the orbicularis oculi muscle. This has detracted surgeons from performing the technical maneuvers necessary for optimal periorbital rejuvenation. A simplified, "five-step" clinical approach based o...

متن کامل

Management of the midface during facial rejuvenation.

The endoscopic midface lift procedure has evolved from experience with postreduction soft tissue repair after facial fracture fixation. The procedure elevates and repositions midface soft tissue, which descends with facial aging; as well, it can correct periorbital congenital abnormalities, such as exorbitism and lateral canthal displacement. The procedure has been refined by the senior author ...

متن کامل

Surgical anatomy of the ligamentous attachments of the lower lid and lateral canthus.

Description of the surgical anatomy of the superficial fascia of the face must include its deep attachments. These attachments have been mapped out for the forehead, temple, and cheek as retaining ligaments. The deep attachments of the orbicularis oculi of the lower lid and lateral canthus have long been recognized in canthopexy surgery but have yet to be properly defined. Six fresh cadavers we...

متن کامل

COSMETIC The Five-Step Lower Blepharoplasty: Blending the Eyelid-Cheek Junction

Dallas, Texas; Beverly Hills, Calif.; and Lyon, France Background: Lower lid blepharoplasty has potential for significant long-lasting complications and marginal aesthetic outcomes if not performed correctly, or if one disregards the anatomical aspects of the orbicularis oculi muscle. This has detracted surgeons from performing the technical maneuvers necessary for optimal periorbital rejuvenat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Plastic and reconstructive surgery

دوره 129 4  شماره 

صفحات  -

تاریخ انتشار 2012