Notification of the Installation of Larger Emergency Core Cooling System (ECCS) Suction Strainers In Accordance With NRC Bulletin 96-03
نویسنده
چکیده
Part of the design inputs for our strainers included the performance of plant-specific testing for behavior of coating debris. A proprietary description of this testing and the results is included in Attachment 2. Attachment 2 of the enclosed information is considered proprietary information by Duke Engineering and Services (DE&S). In accordance with 1OCFR2.790(b)(1), an affidavit attesting to the proprietary nature of the enclosed information is attached. A non-proprietary version of the testing and results is included in Attachment 3.
منابع مشابه
Ladies and Gentlemen:
Provisions in 10 CFR 50.46 require applicants and holders of operating licenses or construction permits to annually notify the Nuclear Regulatory Commission (NRC) of changes and errors in the emergency core cooling system (ECCS) evaluation models. In compliance with this requirement, enclosed is the Southern Nuclear Operating Company's report for Joseph M. Farley Nuclear Plant Units I and 2 for...
متن کاملA Comparison of Scenario Binning Methods for Dynamic Probabilistic Risk Assessment
Dynamic Event Tree (DET) analysis is an effective approach for evaluating plant response during the course of a transient in the presence of modeling or stochastic uncertainties. DET analysis produces very large output datasets, which creates challenges for data management and interpretation. In classical Level 1 PRA, scenarios are grouped mostly according to the states of various active plant ...
متن کاملDesign process of the nanofluid injection mechanism in nuclear power plants
Nanofluids, which are engineered suspensions of nanoparticles in a solvent such as water, have been found to show enhanced coolant properties such as higher critical heat flux and surface wettability at modest concentrations, which is a useful characteristic in nuclear power plants (NPPs). This study attempted to provide an example of engineering applications in NPPs using nanofluid technology....
متن کاملEvaluation of Influencing Factors on the Pull-out Behavior of Suction Caissons
Suction caisson is a type of floor foundation for the offshore structures that is also called suction pile, bucket foundation, suction anchor, or sometimes ridge foundation depending on its application. In two past decades, this type of foundation has been widely used around the world as the fixed offshore foundation, anchor of the floating platforms, as well as the foundation of other marine s...
متن کاملGSI-191: Experimental Studies of Loss-of-Coolant-Accident-Generated Debris Accumulation and Head Loss with Emphasis on the Effects of Calcium Silicate Insulation
ii iii ABSTRACT This report documents experiments conducted to determine the head-loss characteristics associated with calcium silicate insulation debris accumulated on a sump screen. These experiments were performed under the direction of Los Alamos National Laboratory in facilities operated by the Civil Engineering Department of the University of New Mexico. Experiments confirmed that calcium...
متن کامل