Preseismic anomalous telluric current signals observed in Kozu-shima Island, Japan.

نویسندگان

  • Yoshiaki Orihara
  • Masashi Kamogawa
  • Toshiyasu Nagao
  • Seiya Uyeda
چکیده

Monitoring of telluric current, which is practically a synonym for geoelectric potential difference, was conducted on Kozu-shima Island about 170 km south of Tokyo from May 14, 1997 to June 25, 2000. During the monitoring period, 19 anomalous telluric current changes (ATCs) were observed. Their possible correlation with nearby earthquakes was statistically examined by assuming various lead times for different ranges of magnitude and focal distance. The best correlation may be obtained for earthquakes with a magnitude greater than 3.0 occurring within 20 km of focal distance. There were 23 such earthquakes, of which 11 were preceded by ATCs within 30 d. Of these 11 earthquakes, preceding ATCs of 5 and 6 were positive and negative polarities of telluric current, respectively. Their epicenters were spatially well clustered in the east and west of the island. These facts were clearly beyond those expected by chance and led to a simple speculative model.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Heterogeneous electrical structure of Kozu-shima volcanic island, Japan

Nearly twenty anomalous geoelectric field changes were observed before earthquakes at Kozu-shima Island, Japan, from 1997 to 2000. In order to help locating the current sources of the observed anomalous changes, a bipole-dipole resistivity survey was conducted. From the resistivity survey, including current injection into the ground, it was found that various features of the anomalous changes w...

متن کامل

Subterranean electrical structure of Kozu-shima volcanic island, Japan

Following the electric current injection experiment carried out in 2009, a VLF-MT (Very Low Frequency Magnetotelluric) survey has been conducted in Kozu-shima Island to obtain further information on the subterranean electrical structure that might help understanding the results of our monitoring of geoelectric potentials. A number of VAN-type pre-seismic geoelectric potential anomalies were obs...

متن کامل

Electric and magnetic phenomena observed before the volcano-seismic activity in 2000 in the Izu Island Region, Japan.

Significant anomalous changes in the ultra low frequency range (approximately 0.01 Hz) were observed in both geoelectric and geomagnetic fields before the major volcano-seismic activity in the Izu Island region, Japan. The spectral intensity of the geoelectric potential difference between some electrodes on Niijima Island and the third principal component of geomagnetic field variations at an a...

متن کامل

Preseismic Changes of the Level and Temperature of Confined Groundwater related to the 2011 Tohoku Earthquake

Anomalous groundwater changes started three months before the 2011 M9.0 Off the Pacific coast of the Tohoku Earthquake (Tohoku EQ), Japan. Groundwater level and temperature decreased almost simultaneously in a 2000-m well at a spa, Goyo-onsen, in Iwate Prefecture, 155 km northwest of the epicenter. Since the source of Goyo-onsen, located above the edge of a coseismic rupture area of the Tohoku ...

متن کامل

Separation of Train Noise and Seismic Electric Signals from Telluric Current Data by Ica

Recently, detection of seismic electric signals (SESs) in telluric current data (TCD) observed using the VAN method has attracted notice for short-term earthquake prediction. However, since most of the TCD collected in Japan is affected by train noise, detecting SESs in TCD itself is an extremely arduous job. The goal of this research is to derive a method for detecting SESs, which is difficult...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Proceedings of the National Academy of Sciences of the United States of America

دوره 109 47  شماره 

صفحات  -

تاریخ انتشار 2012