Higher Harmonics Beam Loading Compensation for a Broad Band Ma-loaded Rf Cavity

نویسندگان

  • K. Saito
  • M. Fujieda
  • Y. Mori
  • H. Nakayama
  • C. Ohmori
  • Y. Sato
  • S. Sawada
  • M. Souda
  • Y. Tanabe
  • T. Uesugi
  • M. Yamamoto
چکیده

A broad band RF cavity loaded with magnetic alloy cores has been developed for the Japanese Hadron Facility synchrotrons. Its Q-value can be chosen at between 0.5 and 5. To reduce transient beam loading effects, a small Qvalue (< 3) is preferable to shorten the transient period. However, the circulating beam current of up to 7 A will induce a spurious voltage at the accelerating gap, which deforms the gap voltage due to higher harmonics components, if the Q-value is less than 3. The resulting RFbucket distortion may cause the beam loss. Therefore we have designed a beam loading compensation system to suppress the higher harmonics components.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The First Beam Acceleration Test Using High Gradient Cavity at Himac

The HGC loaded with MA cores has been developed[1] for the JHF (Japan Hadron Facility) proton synchrotrons. The maximum voltage of 20 kV has been obtained by the cavity of 40 cm in length. The cavity was driven by a pushpull amplifier using two 150 kW tetrodes. The frequency sweeping from 1 to 5 MHz has been achieved without any tuning circuit because of its broadband characteristics of the MA-...

متن کامل

High Field-Gradient Cavities Loaded with Magnetic Alloys for SynchrotronsInvited

Very high field-gradient has become available by a new Magnetic Alloy (MA)-loaded cavity developed for high intensity proton synchrotrons. The available RF voltage per core is ten times larger than that of the ordinary ferrite core. The maximum voltage of 20 kV has been achieved by the High-Field Gradient Cavity(HGC) of 40 cm in length[1]. Because the intrinsic Q-value of the MA core is low, ac...

متن کامل

Beam Loading Effects in Jhf Synchrotron

Beam loading effects on the rf system of JHF proton synchrotrons have been investigated by both computer simulation and experiment using a low energy electron beam. From the simulation results, it is found that even under the heavy beam loading the beam acceleration becomes stable if applying the beam loading compensation, and the compensation experiment is succeeded on proto-type Magnetic Allo...

متن کامل

Beam Loading Compensation for the Nlc Low Frequency Linacs

The NLC low rf linacs are heavily loaded by a beam of about 130 ns in macropulse length (90 bunches) and a current up to 2.75 Amps. Beam loading voltage generates a large energy spread along the bunch train. This energy spread is critical for lattice design and, if not properly compensated, induces emittance growth and in turn lowers the luminosity of the machine. In this paper, we study the AF...

متن کامل

Updated Impedance Estimate of the Pep-ii Rf Cavity

This paper presents an updated estimate of the higher-order mode impedance spectrum of the RF cavities for the PEP-II B-factory. The cavity is designed for continuous operation at 476 MHz with up to 150 kW wall dissipation and heavy beam loading. To reduce the growth rates of coupled-bunch instabilities the cavity higher-order modes are damped by three rectangular waveguides and broad-band load...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998