Hvac Design Informed by Organizational Simulation

نویسندگان

  • Zhengwei Li
  • Yeonsook Heo
  • Godfried Augenbroe
چکیده

One of the major factors in HVAC design is the occupant load, both in terms of heat gains and fresh air needs. Internal heat gains that result from human occupancy, commonly use a predicted maximum occupancy and an estimated occupancy diversity factor. This may have two problems. First, the maximum number may be far away from true value, Secondly, in a dynamic organizational environment, it is not easy to get a good estimate of the occupancy diversity factor. This paper comes up with a new approach that informs the HVAC design process by organizational simulation. By augmenting the traditional load design procedure with organizational information, it is expected that a more accurate building load estimate can be achieved, resulting in more accurate HVAC sizing. This paper investigates this expectation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and operation optimization of an air conditioning system through simulation: an hour-by-hour simulation study

In the present research, performance validation of a Heating, Ventilation, and Air Conditioning (HVAC) system operating in a library building was conducted. The operating HVAC system was studied in terms of the provided indoor air conditions and energy consumption level. The fieldwork measurements showed that the HVAC system is not capable of providing the desired indoor air conditions based on...

متن کامل

MIMO Robust Control for Heating, Ventilating and Air Conditioning (HVAC) Systems

Potential improvements in heating, ventilating, and air conditioning (HVAC) system performance are investigated through the application of multiple-input, multiple-output (MIMO) robust controllers. This approach differs dramatically from today’s prevalent method of building HVAC controllers using multiple single-input, single-output (SISO) control loops. A simulation model of an experimental HV...

متن کامل

Evolutionary Algorithm with Three Different Permutation Options Used for Preliminary Hvac System Design

This paper discusses an HVAC system design optimization using a detailed simulation method as well as an evolutionary algorithm using three different permutation options. The detailed simulation method was used to evaluate the objective function, i.e. HVAC energy consumption, calculated using DOE-2 software. The variables for the optimization problem were: (i) grouping of the zones served by th...

متن کامل

An Experimental System for Advanced Heating, Ventilating and Air Conditioning (HVAC) Control

While having the potential to significantly improve heating, ventilating and air conditioning (HVAC) system performance, advanced (e.g., optimal, robust and various forms of adaptive) controllers have yet to be incorporated into commercial systems. Controllers consisting of distributed proportional-integral (PI) control loops continue to dominate commercial HVAC systems. Investigation into adva...

متن کامل

Application of Solar Thermal Collectors to Improve the Energy Performance of the Fresh Air HVAC Systems

 In the preset study, the performance of a solar assisted heating, ventilation and air conditioning (HVAC) system in an operating theater building was studied. The yearly performances of the existing HVAC system and the system with the added solar collectors were simulated in terms of energy consumption and provided air conditions using a transient system simulation software (TRNSYS). In t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009