Multiobjective anatomy-based dose optimization for HDR-brachytherapy with constraint free deterministic algorithms.

نویسندگان

  • N Milickovic
  • M Lahanas
  • M Papagiannopoulo
  • N Zamboglou
  • D Baltas
چکیده

In high dose rate (HDR) brachytherapy, conventional dose optimization algorithms consider multiple objectives in the form of an aggregate function that transforms the multiobjective problem into a single-objective problem. As a result, there is a loss of information on the available alternative possible solutions. This method assumes that the treatment planner exactly understands the correlation between competing objectives and knows the physical constraints. This knowledge is provided by the Pareto trade-off set obtained by single-objective optimization algorithms with a repeated optimization with different importance vectors. A mapping technique avoids non-feasible solutions with negative dwell weights and allows the use of constraint free gradient-based deterministic algorithms. We compare various such algorithms and methods which could improve their performance. This finally allows us to generate a large number of solutions in a few minutes. We use objectives expressed in terms of dose variances obtained from a few hundred sampling points in the planning target volume (PTV) and in organs at risk (OAR). We compare two- to four-dimensional Pareto fronts obtained with the deterministic algorithms and with a fast-simulated annealing algorithm. For PTV-based objectives, due to the convex objective functions, the obtained solutions are global optimal. If OARs are included, then the solutions found are also global optimal, although local minima may be present as suggested.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Hybrid Evolutionary Algorithm for Multiobjective Anatomy Based Dose Optimization in HDR Brachytherapy

Multiple objectives must be considered in anatomy based dose optimization for high dose rate (HDR) brachytherapy and a large number of parameters must be optimized to satisfy often competing objectives. For objectives expressed solely in terms of dose variances, deterministic gradient-based algorithms can be applied and a weighted sum approach is able to produce a representative set of non-domi...

متن کامل

Comparison of Evolutionary and Deterministic Multiobjective Algorithms for Dose Optimization in Brachytherapy

We compare two multiobjective evolutionary algorithms, with deterministic gradient based optimization methods for the dose optimization problem in high-dose rate (HDR) brachytherapy. The optimization considers up to 300 parameters. The objectives are expressed in terms of statistical parameters, from dose distributions. These parameters are approximated from dose values from a small number of p...

متن کامل

Application of Multiobjective Evolutionary Algorithms for Dose Optimization Problems in Brachytherapy

In High Dose Rate (HDR) brachytherapy the conventional dose optimization algorithms consider the multiple objectives in form of an aggregate function which combines individual objectives into a single utility value. As a result, the optimization problem becomes single objective, prior to optimization. Up to 300 parameters must be optimized satisfying objectives which are often competing. We use...

متن کامل

Interactive multiobjective optimization for anatomy-based three-dimensional HDR brachytherapy.

In this paper, we present an anatomy-based three-dimensional dose optimization approach for HDR brachytherapy using interactive multiobjective optimization (IMOO). In brachytherapy, the goals are to irradiate a tumor without causing damage to healthy tissue. These goals are often conflicting, i.e. when one target is optimized the other will suffer, and the solution is a compromise between them....

متن کامل

Global convergence analysis of fast multiobjective gradient-based dose optimization algorithms for high-dose-rate brachytherapy.

We consider the problem of the global convergence of gradient-based optimization algorithms for interstitial high-dose-rate (HDR) brachytherapy dose optimization using variance-based objectives. Possible local minima could lead to only sub-optimal solutions. We perform a configuration space analysis using a representative set of the entire non-dominated solution space. A set of three prostate i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 47 13  شماره 

صفحات  -