A luminescent-water soluble inorganic co-crystal for a selective pico-molar range arsenic(III) sensor in water medium.

نویسندگان

  • Biswajit Dey
  • Rajat Saha
  • Priyanka Mukherjee
چکیده

The water solution of an intriguing luminescent 'Inorganic Co-crystal' of Cu(II) monomeric and dimeric units shows extremely selective sensing ability towards inorganic arsenic(III) in water medium in the pico-molar concentration range even in the presence of other cations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Femtomolar level sensing of inorganic arsenic(III) in water and in living-systems using a non-toxic fluorescent probe.

A highly selective femtomolar level sensing of inorganic arsenic(III) as arsenious acid has been accomplished in water medium and in living-systems (on pollen grains of Tecoma stans; Candida albicans cells (IMTECH No. 3018) and Peperomia pellucida stem section) using a non-toxic fluorescent probe of a Cu(II)-complex.

متن کامل

Flow injection on-line sorption preconcentration coupled with hydride generation atomic fluorescence spectrometry for determination of (ultra)trace amounts of arsenic(III) and arsenic(V) in natural water samples.

A flow injection on-line sorption preconcentration and separation in a knotted reactor (KR) was coupled to hydride generation atomic fluorescence spectrometry (HG-AFS) for speciation of inorganic arsenic in natural water samples. The method involved on-line formation of the As(III)-pyrrolidinedithiocarbamate (PDC) complex over a sample acidity of 0.001-0.1 mol L(-1) HCl, its adsorption onto the...

متن کامل

Determination of (ultra)trace amounts of arsenic(III) and arsenic(V) in water by inductively coupled plasma mass spectrometry coupled with flow injection on-line sorption preconcentration and separation in a knotted reactor.

A method has been developed for determination of (ultra)trace amounts of As(III) and As(V) in water by flow injection on-line sorption preconcentration and separation coupled with inductively coupled plasma mass spectrometry (ICPMS) using a knotted reactor (KR). The determination of As(III) was achieved by selective formation of the As(III)-pyrrolidine dithiocarbamate complex over a sample acid...

متن کامل

Organobismuth compounds with the pincer ligand 2,6-(Me2NCH2)2C6H3: monoorganobismuth(III) carbonate, sulfate, nitrate, and a diorganobismuthenium(III) salt.

The reaction of RBiCl(2) (1) [R = 2,6-(Me(2)NCH(2))(2)C(6)H(3)] with Na(2)CO(3) or Ag(2)SO(4) (1 : 1 molar ratio) gave RBiCO(3) (2) and RBiSO(4) (3), respectively. RBi(NO(3))(2) (4) was obtained from RBiCl(2) and AgNO(3) (1 : 2 molar ratio). The ionic complex [R(2)Bi][W(CO)(5)Cl] (6) was obtained from R(2)BiCl (5) and W(CO)(5)(THF), following an unusual chlorine transfer from bismuth to tungste...

متن کامل

Molybdenum blue spectrophotometry for trace arsenic in ground water using a soluble membrane filter and calcium carbonate column.

An improved molybdenum blue spectrophotometry using a soluble membrane filter and CaCO(3)-column was proposed for determining arsenic in drinking water supplied from ground water in the presence of phosphate. A 100 mL sample solution containing 0.5 - 10 μg arsenic was passed through a CaCO(3)-column to remove phosphate, arsenate (As(V)). Arsenite (As(III)) which was not retained on the column...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chemical communications

دوره 49 63  شماره 

صفحات  -

تاریخ انتشار 2013