Robust large field-of-view water selective imaging at 3T with parallel transmission
نویسندگان
چکیده
Introduction: Spectral fat suppressed or water selective imaging (e.g. using 1331 binomial pulses) for large fields-of-view is difficult to achieve, particularly at higher field because of problems in achieving a high-quality shim of the static B0 field. Off resonance effects cause the water and fat resonances to be position dependent, causing water only selection/fat suppression to fail in some regions of the image, most frequently at the edge of the field of view. The recent development of parallel transmission (PTx) has provided greater control over the radio-frequency (B1) field; and while this can be used to influence the homogeneity of flip angle (e.g. RF shimming [1]), we demonstrate that it can also be used to mitigate off resonance problems and so make water selective imaging more robust at 3T.
منابع مشابه
Water Selective Imaging and bSSFP Banding Artifact Correction in Humans and Small Animals at 3T and 7T, Respectively
INTRODUCTION The purpose of this paper is to develop an easy method to generate both fat signal and banding artifact free 3D balanced Steady State Free Precession (bSSFP) images at high magnetic field. METHODS In order to suppress fat signal and bSSFP banding artifacts, two or four images were acquired with the excitation frequency of the water-selective binomial radiofrequency pulse set On R...
متن کاملSAR optimised local B1 + shimming for cardiac imaging at 3T – a multi-model study
Target Audience: This work will benefit those interested in using parallel transmission MRI to reduce SAR in cardiac MR Purpose: Cardiac imaging at high field (3T and above) suffers from image quality issues due to greater B1 + inhomogeneities and is frequently limited by SAR, which constrains the speed at which scans can be run without exceeding regulatory limits. Parallel transmission can mit...
متن کاملEnhanced Slab Selective Brain Imaging at 3T using Wide Band Tailored RF pulses
Introduction T1 weighted brain imaging at 3T for both clinical and neuroscience applications is often done using slab selective MPRAGE [1] sequences that provide flexible 3D coverage. RF field (B1) non-uniformity is an inherent problem for high field MRI and for this type of sequence results in variable image contrast. In order to compensate for this, various B1 inhomogeneity mitigating RF puls...
متن کاملHigh-flip-angle slice-selective parallel RF transmission with 8 channels at 7 T.
At high magnetic field, B(1)(+) non-uniformity causes undesired inhomogeneity in SNR and image contrast. Parallel RF transmission using tailored 3D k-space trajectory design has been shown to correct for this problem and produce highly uniform in-plane magnetization with good slice selection profile within a relatively short excitation duration. However, at large flip angles the excitation k-sp...
متن کامل3T Coronary MRA using 3D Multi-interleaved Multi-echo Acquisition and VARPRO Fat-water Separation
Introduction: Coronary MR Angiography is a valuable tool for non-invasive assessment of coronary arteries. Presently, contrastenhanced, fat-saturated, ECG-triggered and navigator-gated 3D spoiled gradient-echo sequence is employed for whole-heart Coronary MRA at 3T. However, large static field variations at 3T frequently result in non-uniform fat-suppression over the field-of-view (FOV), obscur...