Anatomical plate configuration affects mechanical performance in distal humerus fractures.
نویسندگان
چکیده
BACKGROUND Because of strong loads acting in the elbow joint, intraarticular fractures with a methaphyseal comminuted fracture site at the distal humerus demand a lot from the osteosynthetic care. Ambiguities arise concerning to the anatomic position of the implants and the resulting mechanic performance. The aim of this biomechanical study was to compare the performance of different anatomical plate configurations for fixation of comminuted distal humerus fractures within one system. METHODS In an artificial bone model two perpendicular and one parallel plating configuration of a dedicated elbow plating system were compared with respect to system rigidity (flexion and extension) and dynamic median fatigue limit (extension). The flexion tests were conducted under 75° and the extension tests under 5°. Furthermore, the relative displacements were recorded. As a fracture model an AO C 2.3-fracture on an artificial bone (4th Gen. Sawbone) was simulated via double osteotomy in sagittal and transversal plane. FINDINGS Large differences in mechanical performance were observed between flexion and extension loading modes. In extension the parallel configuration with lateral and medial plates achieved the highest bending stiffness and median fatigue limit. In flexion the highest bending stiffness was reached by the construct with a medial and a postero-lateral plate. Failure of the implant system predominantly occurred at the screw-bone interface or by fatigue of the plate around the screw holes. INTERPRETATION All three plate configurations provided sufficient mechanical stability to allow early postoperative rehabilitation with a reduced loading protocol. Although the individual fracture pattern determines the choice of plate configuration, the parallel configuration with lateral and medial plates revealed biomechanical advantages in extension only.
منابع مشابه
A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate
Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...
متن کاملBiomechanical comparison of two different periarticular plating systems for stabilization of complex distal humerus fractures.
BACKGROUND Complex intra-articular distal humerus fractures are relatively uncommon injuries but are fraught with poor outcomes such as malunion, elbow stiffness and deformity. Various types of internal fixation screw-plate constructs have been developed to improve fixation. Specifically, a 90 degrees offset periarticular system lowers the profile on the lateral epicondyle, yet it is unclear ho...
متن کاملDISPLACED- COMMINUTED INTRAARTICULAR FRACTURES OF THE ADULT DISTAL HUMERUS: FUNCTIONAL RESULTS AFTER INTERNAL FIXATION
Background: Intra-articular T- type or Y- type fractures of the distal end of the humerus are relatively rare, and consequently few surgeons will be able to attain extensive experience with the surgical treatment of these injuries. The current emphasis is on operative intervention with rigid internal fixation and early mobilization. Methods: In this prospective and retrospective study, we r...
متن کاملRisk factors of loss reduction after percutaneous fixation in supracondylar humerus in pediatric: a descriptive-analytical study
Background & Aims: supracondylar humerus fracture is one of the most common pediatric elbow fractures accounting for about 16% of the pediatric fractures. Loss of reduction is one of the complications after closed and percutaneous fixation. This research is aimed to investigate the factors involved in the loss of reduction. Method: In this descriptive study, the children with supracondylar hum...
متن کاملMid-term results of complex distal humeral fractures.
The aim of this study was to assess outcomes following open reduction and internal fixation in complex fractures of the distal humerus. Between 2000 and 2006, 34 patients were operated for complex fractures of the distal humerus. Bone fixation was obtained with a reverse Y-shaped reconstruction plate in 13 cases and with double plating in 21 cases. At final follow-up, all the patients were asse...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical biomechanics
دوره 25 10 شماره
صفحات -
تاریخ انتشار 2010